NOTE Blue coloured text within this document indicates text that will be aligned with the future MME immunity publication CISPR35. This International Standard applies to multimedia equipment (MME) as defined in 3.1.24 and having a rated r.m.s. AC or DC supply voltage not exceeding 600V. Text deleted MME intended primarily for professional use is within the scope of this publication. The emission requirements in this standard are not intended to be applicable to the intentional transmissions from a radio communication device operated in accordance with the ITU-R Radio Regulations, nor to any spurious emissions related to these intentional transmissions. Equipment, for which emission requirements in the frequency range covered by this publication are explicitly formulated in other CISPR publications is excluded from the scope of this publication. In-situ testing is outside the scope of this publication. This publication covers two classes of MME (Class A and Class B). The MME classes are specified in Clause4. The objectives of this publication are: to establish requirements which provide an adequate level of protection of the radio spectrum, allowing radio services to operate as intended in the frequency range 9kHz to 400GHz; to specify procedures to ensure the reproducibility of measurement and the repeatability of results.