BS EN 599-1 : 2009
Current
The latest, up-to-date edition.
DURABILITY OF WOOD AND WOOD-BASED PRODUCTS - EFFICACY OF PREVENTIVE WOOD PRESERVATIVES AS DETERMINED BY BIOLOGICAL TESTS - PART 1: SPECIFICATION ACCORDING TO USE CLASS
Hardcopy , PDF
English
01-01-2009
Introduction
1 Scope
2 Normative references
3 Terms, definitions, abbreviations and symbols
4 Assignment to use class(es)
5 Efficacy
6 Tests for efficacy according to use class
7 Derivation of critical values
8 Marking
9 Product identification
Annex A (informative) - Guidance on re-testing after
making variations in product formulation
Annex B (informative) - Production control
Annex C (informative) - Methods of application
Annex D (informative) - Type of wood
Annex E (informative) - Artificial ageing procedures
Annex F (informative) - Significance of specific
biological agents
Annex G (informative) - Minimum efficacy requirements
Annex H (normative) - Validity of test results from former
standards after their revision
Bibliography
Defines for each of the five use classes defined in EN 335-1, the biological tests required for evaluating the efficacy of wood preservatives for the preventive treatment of solid timber, together with the minimum ageing tests required for the respective use class.
| Committee |
B/515
|
| DevelopmentNote |
Supersedes 91/58200 DC (09/2005) Supersedes 07/30088601 DC. (02/2010) 2009 Edition Re-Issued in January 2014 and incorporates AMD 1 2013. Supersedes 13/30282196 DC. (01/2014)
|
| DocumentType |
Standard
|
| Pages |
44
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NEN EN 599-1 : 2009 + A1 2013 | Identical |
| I.S. EN 599-1:2009 | Identical |
| NS EN 599-1 : 2009 + A1 2013 | Identical |
| NBN EN 599-1 : 2009 + A1 2014 | Identical |
| DIN EN 599-1:2014-03 | Identical |
| EN 599-1:2009+A1:2013 | Identical |
| NF EN 599-1 : 2009 + A1 2014 | Identical |
| EN 599-1:2009 | Equivalent |
| UNE-EN 599-1:2010 | Identical |
| 12/30263952 DC : 0 | BS EN 61048:2006+A1 - AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS |
| 08/30143158 DC : DRAFT AUG 2008 | BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION |
| BS 5534(2014) : 2014 | SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
| BS DD239(1998) : 1998 | RECOMMENDATIONS FOR PRESERVATION OF TIMBER |
| BS 8417(2011) : 2011 | PRESERVATION OF WOOD - CODE OF PRACTICE |
| BS 644:2012 | Timber windows and doorsets. Fully finished factory-assembled windows and doorsets of various types. Specification |
| BS 644:2009 | Timber windows. Fully finished factory-assembled windows of various types. Specification |
| 12/30218393 DC : 0 | BS 644 - TIMBER WINDOWS AND DOORSETS - FULLY FINISHED FACTORY-ASSEMBLED WINDOWS AND DOORSETS OF VARIOUS TYPES - SPECIFICATION |
| BS 4261:1999 | Wood preservation. Vocabulary |
| BS 8417:2003 | Preservation of timber. Recommendations |
| BS 5534(2003) : 2003 | CODE OF PRACTICE FOR SLATING AND TILING (INCLUDING SHINGLES) |
| 13/30271503 DC : 0 | BS 5534 - SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
| 10/30212804 DC : 0 | BS 8417 - PRESERVATION OF WOOD - CODE OF PRACTICE |
| BS 144:1997 | Specification for coal tar creosote for wood preservation |
| ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
| EN 20-2:1993 | Wood preservatives - Determination of the protective effectiveness against Lyctus brunneus (Stephens) - Part 2: Application by impregnation (Laboratory method) |
| CEN/TS 839:2008 | Wood preservatives - Determination of the protective effectiveness against wood destroying basidiomycetes - Application by surface treatment |
| EN 335-2:2006 | Durability of wood and wood-based products - Definition of use classes - Part 2: Application to solid wood |
| EN 350-1:1994 | Durability of wood and wood-based products - Natural durability of solid wood - Part 1: Guide to the principles of testing and classification of the natural durability of wood |
| EN 351-1:2007 | Durability of wood and wood-based products - Preservative-treated solid wood - Part 1: Classification of preservative penetration and retention |
| EN 84:1997 | Wood preservatives - Accelerated ageing of treated wood prior to biological testing - Leaching procedure |
| EN 152:2011 | Wood preservatives - Determination of the protective effectiveness of a preservative treatment against blue stain in wood in service - Laboratory method |
| EN 49-1:2016 | Wood preservatives - Determination of the protective effectiveness against Anobium punctatum (De Geer) by egg-laying and larval survival - Part 1: Application by surface treatment (Laboratory method) |
| EN 47:2016 | Wood preservatives - Determination of the toxic values against larvae of Hylotrupes bajulus (Linnaeus) - (Laboratory method) |
| EN 330:2014 | Wood preservatives - Determination of the relative protective effectiveness of a wood preservative for use under a coating and exposed out-of-ground contact - Field test: L-joint method |
| EN 275:1992 | Wood preservatives - Determination of the protective effectiveness against marine borers |
| EN 1001-2:2005 | Durability of wood and wood based products - Terminology - Part 2: Vocabulary |
| EN 118:2013 | Wood preservatives - Determination of preventive action against Reticulitermes species (European termites) (Laboratory method) |
| ENV 807:2001 | Wood preservatives - Determination of the effectiveness against soft rotting micro-fungi and other soil inhabiting micro-organisms |
| EN 350-2:1994 | Durability of wood and wood-based products - Natural durability of solid wood - Part 2: Guide to natural durability and treatability of selected wood species of importance in Europe |
| EN 46-1:2016 | Wood preservatives - Determination of the preventive action against recently hatched larvae of Hylotrupes bajulus (Linnaeus) - Part 1: Application by surface treatment (laboratory method) |
| EN 49-2:2015 | Wood preservatives - Determination of the protective effectiveness against Anobium punctatum (De Geer) by egg-laying and larval survival - Part 2: Application by impregnation (Laboratory method) |
| EN 46-2:2016 | Wood preservatives - Determination of the preventive action against recently hatched larvae of Hylotrupes bajulus (Linnaeus) - Part 2: Ovicidal effect (laboratory method) |
| EN 117:2012 | Wood preservatives - Determination of toxic values against Reticulitermes species (European termites) (Laboratory method) |
| EN 460:1994 | Durability of wood and wood-based products - Natural durability of solid wood - Guide to the durability requirements for wood to be used in hazard classes |
| EN 599-2:2016 | Durability of wood and wood-based products - Efficacy of preventive wood preservatives as determined by biological tests - Part 2: Labelling |
| EN 73:2014 | Wood preservatives - Accelerated ageing of treated wood prior to biological testing - Evaporative ageing procedure |
| ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
| EN 252:2014 | Field test method for determining the relative protective effectiveness of a wood preservative in ground contact |
| EN 335-1:2006 | Durability of wood and wood- based products - Definition of use classes - Part 1: General |
| EN 20-1:1992 | Wood preservatives - Determination of the protective effectiveness against Lyctus Brunneus (Stephens) - Part 1: Application by surface treatment (laboratory method) |
| EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |