    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Protection levels
    5 Constructional requirements for pressurized
       enclosures
    6 Temperature limits
    7 Safety provisions and safety devices (except for
       static pressurization)
    8 Safety provisions and safety devices for static
       pressurization
    9 Supply of protective gas
    10 Pressurized equipment with an internal
       source of release
    11 Release conditions
    12 Design requirements for the containment system
    13 Protective gas and pressurizing techniques
       when there is an internal source of release
    14 Ignition-capable equipment
    15 Internal hot surfaces
    16 Type verification and tests
    17 Routine tests
    18 Marking
    19 Instructions
    Annex A (normative) Purging and dilution tests
    Annex B (informative) Examples of functional
            sequence diagram
    Annex C (informative) Examples of the changes in
            pressure in ducts and enclosures
    Annex D (informative) Information to be provided
            to the user
    Annex E (normative) Classification of the type of
            release within enclosures
    Annex F (informative) Examples for the use of the
            dilution area concept
    Annex G (normative) Internal Cells and Batteries for
            Level of Protection 'pxb' and
            Level of Protection 'pyb'
    Annex H (normative) Internal Cells and Batteries
            for Level of Protection 'pzc'
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with
             their corresponding European
             publications
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EU Directives
    Annex ZY (informative) - Significant changes
             between this European Standard
             and EN 60079-2:2007

    Abstract - (Show below) - (Hide below)

    Defines the specific requirements for the construction and testing of electrical equipment with pressurized enclosures, of type of protection 'p', intended for use in explosive gas atmospheres or explosive dust atmospheres.

    Scope - (Show below) - (Hide below)

    This part of IEC60079 contains the specific requirements for the construction and testing of electrical equipment with pressurized enclosures, of type of protection “p??, intended for use in explosive gas atmospheres or explosive dust atmospheres. It also includes the requirements for pressurized enclosures containing a limited release of a flammable substance. This standard supplements and modifies the general requirements of IEC60079-0. Where a requirement of this standard conflicts with a requirement of IEC60079-0, the requirements of this standard take precedence. This standard does not include the requirements for: pressurized enclosures where the containment system may release air with an oxygen content greater than normal, or oxygen in combination with inert gas where the oxygen is in a proportion greater than 21%. pressurized rooms or analyser houses; see IEC60079-13; pressurized enclosures used where “explosives?? or pyrotechnics are present; pressurized enclosures used where hybrid mixtures of gas/vapour and combustible dust are present; pressurized enclosures used where pyrophoric substances such as explosives or propellants containing their own oxidizers are present pressurized enclosures with an internal source of release of combustible dust. NOTE When the user acts in the role of the manufacturer, it is typically the user’s responsibility to ensure that all relevant parts of this standard are applied to the manufacturing and testing of the equipment.

    General Product Information - (Show below) - (Hide below)

    Committee EXL/31
    Development Note Supersedes BS EN 50016 & 97/202260 DC. (07/2004) Supersedes 04/30117249 DC. (01/2008) Supersedes BS EN 61241-4. (01/2015)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EI Model code of safe practice Part 15:2015 MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS
    12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
    BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
    EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
    09/30205684 DC : 0 BS 7375 - CODE OF PRACTICE FOR DISTRIBUTION OF ELECTRICITY ON CONSTRUCTION AND BUILDING SITES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
    IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    EN 60079-26:2015 Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
    EN 60079-1:2014 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
    EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
    IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
    EN 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    EN 60079-28:2015 Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
    IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
    EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    EN 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
    EN 60079-5:2015 Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
    IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
    EN 60034-5:2001/A1:2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective