• Shopping Cart
    There are no items in your cart

BS EN 60110-1:1998

Current

Current

The latest, up-to-date edition.

Power capacitors for induction heating installations General

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-12-1998

€263.42
Excluding VAT
Summarise this standard

1 General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
1.4 Service conditions
2 Quality requirements and tests
2.1 Test requirements
2.2 Classification of tests
2.3 Capacitance measurement
2.4 Measurement of the tangent of the loss angle (tan) of
        of a capacitor
2.5 Voltage test between terminals (routine test)
2.6 Voltage test between terminals and container
2.7 Test on internal discharge device
2.8 Sealing test
2.9 Thermal stability test
2.10 Capacitor losses test
2.11 Capacitance as a function of temperature
2.12 Sealing test of cooling ducts, if any
2.13 Self-healing test (for self-healing metallized dielectric
        capacitors)
2.14 Short-circuit discharge test
2.15 Ageing test (see IEC 60110-2)
2.16 Destruction test (see IEC 60110-2)
2.17 Disconnecting test on internal fuses, if any (see IEC 60110-2)
3 Overloads
3.1 Maximum permissible voltage
3.2 Switching voltages
3.3 Maximum permissible current
4 Safety requirements
4.1 Creepage distances
4.2 Discharge device
4.3 Container connections
4.4 Protection of the environment
4.5 Additional safety requirements
5 Markings
5.1 Marking of the capacitor unit
5.2 Marking of the bank
6 Guide for installation and operation
6.1 General
6.2 Measures to obtain adequate cooling
6.3 Choice of rated voltage, current and output
6.4 Capacitors for frequent switching on load
6.5 Choice of switchgear and switching methods for switching
        on load
6.6 Switching of capacitors with fuses
6.7 Operation with varying frequency
6.8 Choice of the highest voltage for equipment of a capacitor
        bank
6.9 Shunt capacitors connected in series
6.10 Series capacitors
6.11 Connecting leads
6.12 Live parts along water supply
6.13 Post insulators
6.14 Danger of freezing for water cooled capacitors
Annex A (normative) methods of measuring the losses on air-cooled
        self-and forced-ventilated capacitors
Annex B (informative) formulae for capacitors and installations
Annex C (informative) bibliography
Annex ZA Normative references to international publications with
         their corresponding European publications

Applicable to indoor capacitor units and banks used particularly for power factor correction with controlled a.c. voltage systems up to 50 Hz, 3.6k V.

Committee
W/-
DevelopmentNote
Also numbered as IEC 60110-1 Supersedes 97/202783 DC (05/2005)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
I.S. EN 60110-1:2003 Identical
NF EN 60110-1 : 1998 Identical
NBN EN 60110-1 : 1998 Identical
EN 60110-1:1998 Identical
DIN EN 60110-1:1999-09 Identical
UNE-EN 60110-1:1999 Identical

€263.42
Excluding VAT