BS EN 60146-1-3:1993
Current
The latest, up-to-date edition.
Semiconductor convertors. General requirements and line commutated convertors Transformers and reactors
Hardcopy , PDF
English
15-05-1993
Cooperating organizations
National foreword
Foreword
1 Scope
2 Normative references
3 Rated values for convertor transformers
3.1 Rated current values
3.2 Temperature limits of cooling media
4 Losses and voltage drops in transformers and
reactors
4.1 Losses in the transformer windings
4.2 Losses in interphase transformers, current
balancing reactors, series-smoothing reactors,
transductors and other current regulating
accessories
4.3 Voltage drops in transformers and reactors
5 Tests for convertor transformers
5.1 Measurement of commutating reactance and
determination of inductive voltage drop (type test)
5.2 Short-circuit test (type test and routine test)
5.3 Temperature rise test (type test)
Annex
A (normative) Corrections to be applied when cooling
medium temperature is higher than standard
ZA (normative) Other international publications
quoted in this standard with the references of the
relevant European publications
Tables
1 Temperature rise limits
2 Connections and calculation factors
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references
Relates to the characteristics wherein convertor transformers differ from ordinary power transformers. Includes the following sections: rated values for convertor transformers; losses and voltage drops in transformers and reactors; tests for convertor transformers.
Committee |
PEL/22
|
DevelopmentNote |
Also numbered as IEC 60146-1-3 Together with BS EN 60146-1.1, it supersedes BS 4417(1969) Supersedes 92/17370 DC (08/2003)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
SupersededBy | |
Supersedes |
This Part 1-3 of the International Standard relates, in general, to those characteristics wherein convertor transformers differ from ordinary power transformers. In all other respects, the rules specified in IEC 76 shall apply to convertor transformers also, as far as they are not in contradiction with this standard.
It should be borne in mind that a rectifier transformer operates with non-sinusoidal current waveshape. In single-way connection, the current in each cell winding contains a d.c. component which calls for special attention in design and testing. In some cases, a special design is necessary when external short-circuits and cell failures would cause abnormal stress.
For certain types of transformers, the waveshape of the normal operating voltage is non-sinusoidal. The core loss of such equipment is to be determined by applying a sinusoidal voltage having the same half-cycle arithmetic mean value and the same fundamental frequency as the voltage applied in service.
Standards | Relationship |
SN EN 60146-1-3 : 1993 | Identical |
EN 60146-1-3:1993 | Identical |
UNE-EN 60146-1-3:1996 | Identical |
NF EN 60146-1-3 : 1993 | Identical |
I.S. EN 60146-1-3:1993 | Identical |
DIN EN 60146-1-3 : 1994 | Identical |
BS 171:1970 | Specification for power transformers |
BS EN 60146-1-1:2010 | Semiconductor converters. General requirements and line commutated converters Specification of basic requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.