BS EN 60317-49:2012
Current
The latest, up-to-date edition.
Specifications for particular types of winding wires Glass-fibre wound high temperature resin or varnish impregnated, bare or enamelled round copper wire, temperature index 180
Hardcopy , PDF
English
30-04-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, general notes and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to hydrolysis and to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines requirements of glass-fibre wound resin or varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180.
Committee |
W/-
|
DevelopmentNote |
Supersedes 97/261372 DC (05/2005) Supersedes 11/30247695 DC. (11/2012)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60317 specifies the requirements of glass-fibre wound resin or varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180. The impregnating agent can be, for instance, polyester or polyesterimide resin based.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
Standards | Relationship |
IEC 60317-49:2012/COR1:2013 | Identical |
EN 60317-49:2012 | Identical |
I.S. EN 60317-49:2012 | Identical |
NBN EN 60317-49 : 2012 | Identical |
NF EN 60317-49 : 2013 | Identical |
IEC 60317-49:2012 | Identical |
DIN EN 60317-49:2013-06 | Identical |
SN EN 60317-49 : 2000 | Identical |
UNE-EN 60317-49:2013 | Identical |
IEC 60317-0-6:2001+AMD1:2006 CSV | Specifications for particular types of winding wires - Part 0-6: General requirements - Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire |
EN 60317-0-6:2001/A1:2006 | SPECIFICATION FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-6: GENERAL REQUIREMENTS - GLASS-FIBRE WOUND RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.