BS EN 60320-2-4 : 2006
Current
The latest, up-to-date edition.
APPLIANCE COUPLERS FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 2-4: COUPLERS DEPENDENT ON APPLIANCE WEIGHT FOR ENGAGEMENT
Hardcopy , PDF
English
01-01-2006
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Standard ratings
7 Classification
8 Marking
9 Dimensions and compatibility
10 Protection against electric shock
11 Provision for earthing
12 Terminals and terminations
13 Construction
14 Moisture resistance
15 Insulation resistance and electric strength
16 Forces necessary to insert and withdraw the connector
17 Operation of contacts
18 Resistance to heating of appliance couplers for hot
conditions or very hot conditions
19 Breaking capacity
20 Normal operation
21 Temperature rise
22 Cords and their connection
23 Mechanical strengthwith
24 Resistance to heat and ageing
25 Screws, current-carrying parts and connections
26 Creepage distances, clearances and distances through
insulation
27 Resistance of insulating material to heat, fire and
tracking
28 Resistance to rusting
29 Electromagnetic compatibility (EMC) requirements
Annex AA (normative) - Proof tracking test
Annex BB (normative) - Needle flame test
Annex CC (normative) - Apparatus for the test of
Subclause 14.2
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to two-pole appliance couplers for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar general purposes and intended for incorporation or integration within electric appliances or other electric equipment of multi-part construction for 50 Hz or 60 Hz supply which depend on the weight of the appliance to ensure correct engagement.
Committee |
PEL/23/3
|
DevelopmentNote |
To be read in conjunction with BS EN 60320-1 Supersedes 04/30114302 DC (05/2006) 2006 Edition Re-Issued in February 2010 & incorporates AMD 1 2009. Supersedes 08/30191281 DC. (02/2010)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 60320-2-4:2005+AMD1:2009 CSV | Identical |
UNE-EN 60320-2-4:2007 | Identical |
NF EN 60320-2-4 : 2006 AMD 1 2010 | Identical |
SN EN 60320-2-4 : 2006 | Identical |
I.S. EN 60320-2-4:2006 | Identical |
NBN EN 60320-2-4 : 2006 AMD 1 2010 | Identical |
EN 60320-2-4 : 2006 AMD 1 2009 | Identical |
DIN EN 60320-2-4 : 2010 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60320-1:2015 | Appliance couplers for household and similar general purposes - Part 1: General requirements |
IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
IEC 60320-2-3:1998+AMD1:2004 CSV | Appliance couplers for household and similar general purposes - Part 2-3: Appliance couplers with a degree of protection higher than IPX0 |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60320-2-2:1998 | Appliance couplers for household and similar general purposes - Part 2-2: Interconnection couplers for household and similar equipment |
ISO 9772:2012 | Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
EN 60320-2-2:1998 | Appliance couplers for household and similar general purposes - Part 2-2: Interconnection couplers for household and similar equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60320-1:2015/AC:2016 | APPLIANCE COUPLERS FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60320-1:2015/COR1:2016) |
EN 60320-2-3:1998/A1:2005 | APPLIANCE COUPLER FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 2-3: APPLIANCE COUPLER WITH A DEGREE OF PROTECTION HIGHER THAN IPX0 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-