BS EN 60406:1997
Current
The latest, up-to-date edition.
Specification for radiographic cassettes and mammographic cassettes used for medical X-ray diagnosis
Hardcopy , PDF
English
15-08-1997
1 Scope
2 Normative references
3 Terminology
3.1 Degree of requirements
3.2 Use of terms
3.3 Defined term
4 Radiographic cassettes (except mammographic
cassettes)
4.1 Dimensions
4.2 Denomination
4.3 Preferred nominal sizes
4.4 Outer dimensions
4.5 Outer geometrical accuracy
4.6 Inner geometrical accuracy
4.7 Quality of materials
4.8 Design
5 Mammographic cassettes
5.1 Dimensions
5.2 Denomination
5.3 Preferred nominal sizes
5.4 Outer dimensions
5.5 Outer geometrical accuracy
5.6 Inner geometrical accuracy
5.7 Quality of materials
5.8 Design
5.9 Compression
5.10 Film-thorax distance
5.11 Free field for the radiation detector
Tables
1 Dimensions of radiographic cassettes
2 Dimensions of mammographic cassettes
E.1 Sizes that have an origin in inch sizes
Figures 1 Outside dimensions
2 Mammographic cassette with free field for the radiation
detector (minimum dimensions) for stereotactic biopsy
Annexes
A Test for light-proofness
B Test for film-screen contact
C Test for film-screen contact for mammography
D Terminology - Index of defined terms
E Metric conversions
ZA (normative) Normative references to international
publications with their corresponding European
publications
Concerned with the manufacturing of radiographic and mammographic cassettes for use with radiographic screens in medical practice. Not applicable to special cassettes, ie with built-in anti-scatter grids or simultaneous tomography. Ensures that x-ray equipment can be used with radiographic cassettes from different manufacturers.
Committee |
CH/62/2
|
DevelopmentNote |
Also numbered as IEC 60406 Supersedes 94/505828 DC and BS 7534(1991) (11/2005)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard deals with the manufacture of radiographic cassettes and mammographic cassettes intended to be used with radiographic screens in medical practice. This standard does not apply to special cassettes (such as cassettes with built-in anti-scatter grids, cassettes for simultaneous tomography). It is provided to ensure that X-ray equipment can be operated with radiographic cassettes of different manufacturers.
Standards | Relationship |
SN EN 60406 : 1997 | Identical |
EN 60406:1997 | Identical |
I.S. EN 60406:1998 | Identical |
NBN EN 60406 : 1997 | Identical |
UNE-EN 60406:2000 | Identical |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
EN 61267:2006 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 60658:1979 | Radiographic intensifying screens for medical use - Dimensions |
ISO 2092:1981 | Light metals and their alloys Code of designation based on chemical symbols |
EN 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
HD 501 : 200S1 | MEDICAL RADIOLOGY - TERMINOLOGY |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.