• BS EN 60480:2004

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use

    Available format(s):  Hardcopy, PDF

    Superseded date:  07-06-2019

    Language(s):  English

    Published date:  24-08-2005

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
       3.1 General terms
       3.2 Material aspects
       3.3 Environmental aspects
    4 Typical applications of SF[6]
    5 Impurities and their sources
       5.1 Introductory remark
       5.2 Impurities from handling and in service
       5.3 Impurities in equipment having only an insulating
            function
       5.4 Impurities in switching equipment
       5.5 Impurities from internal arcs
    6 Environmental aspects
       6.1 Introductory remark
       6.2 Impact on the ecosystem
       6.3 Ozone depletion
       6.4 Greenhouse effect
       6.5 Decomposition products
       6.6 Conclusion
    7 Health and safety
       7.1 Introductory remark
       7.2 Precautions necessary with SF[6]
       7.3 Necessary precautions with used SF[6]
       7.4 Health considerations
    8 Quality specification for re-use of SF[6] in new or
       existing switchgear
       8.1 Decision flowchart for SF[6] removed from electrical
            equipment for treatment
       8.2 Maximum acceptable impurity levels for re-use of SF[6]
    9 Analytical methods for SF[6] and their significance
       9.1 General
       9.2 On-site analysis
       9.3 Laboratory analysis
    10 Handling, storage and transportation
       10.1 Introductory remark
       10.2 Gas handling equipment
       10.3 General safety requirements
       10.4 Condition of the SF[6] in an enclosure
       10.5 Removing used SF[6] from an enclosure
       10.6 Storage and transportation of used SF[6]
    Annex A (informative) Derivation of maximum tolerable moisture
                           for re-use
    Annex B (informative) Description of the different methods of
                           analysis (on-site and laboratory)
    Annex C (informative) Reclaiming recommendations and
                           procedures on-site
    Annex ZA (normative) Normative references to international
                           publications with their corresponding
                           European publications
    Bibliography
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Specifies the re-use of sulfur hexafluoride (SF[6]) after removal from electrical equipment (for maintenance, or at the end of life).

    Scope - (Show below) - (Hide below)

    Concerns the re-use of sulfur hexafluoride (SF 6) after removal from electrical equipment (for maintenance, or at the end of life). This standard recommends procedures for reclaiming used SF 6 and for restoring its quality to an acceptable level, which would allow the filling of new or existing electrical equipment. This standard provides guidance to operational and maintenance personnel for the testing and safe handling of used SF 6 . The main changes with respect to the previous edition are listed below:
    - updating of standard as it relates to environmental issues, storage and analytical methods;
    - addition of specification for the re-use of gas;
    - inclusion of a regeneration process for sulfur hexafluoride taken from electrical equipment.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/10
    Development Note Supersedes 99/245181 DC. (09/2005) Supersedes BS 5209(1975). (01/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 6867:2013 Maintenance of electrical switchgear and controlgear for voltages above 36 kV. Code of practice
    BS 6626:2010 Maintenance of electrical switchgear and controlgear for voltages above 1 kV and up to and including 36 kV. Code of practice
    13/30174947 DC : 0 BS 6867 - MAINTENANCE OF ELECTRICAL SWITCHGEAR AND CONTROLGEAR FOR VOLTAGES ABOVE 36 KV - CODE OF PRACTICE

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
    IEC 60050-212:2010 International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases
    IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment
    IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
    EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
    IEC 60376B:1974 Second supplement: Clause 26
    IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
    ISO 14040:2006 Environmental management Life cycle assessment Principles and framework
    IEC 60376A:1973 First supplement: Section Thirteen: Mineral oil content
    • Access your standards online with a subscription