1 Scope and object
2 Test equipment
3 Test specimen
4 Test procedure
5 Warning
6 Details to be specified
Figures
1 Details of thermocouple
2 Details of firewall connector fixture
3 Firewall connector fixture assembly
4 Firewall connector test set-up
5 Schematic circuit for testing firewall connectors
Table 1 Firewall connector test currents
This specification is used for testing electromechanical components within the scope of IEC technical committee 48.
Committee |
EPL/48
|
DevelopmentNote |
Also numbered as IEC 60512-20-2. (07/2001) Supersedes 96/203744 DC. (10/2005)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Describes a standard test method to assess the ability of a connector to withstand specified flame and vibration during a 20 min exposure by providing specified electrical performance for the first 6 min of exposure and preventing the flame from penetrating the fireproof bulkhead on which the connector is mounted throughout the test.
Standards | Relationship |
UNE-EN 60512-20-2:2001 | Identical |
DIN EN 60512-20-2:2001-04 | Identical |
I.S. EN 60512-20-2:2001 | Identical |
SN EN 60512-20-2 : 2000 | Identical |
NF EN 60512-20-2 : 2001 | Identical |
EN 60512-20-2:2000 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.