BS EN 60570:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Electrical supply track systems for luminaires
Hardcopy , PDF
10-04-2020
24-09-2003
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 General test requirements
6 Marking
7 General requirements and ratings
8 Construction
9 Creepage distances and clearances
10 Terminals
11 External and internal wiring
12 Thermal endurance and operating temperatures
13 Protection against electric shock
14 Resistance to humidity
15 Insulation resistance and electric strength
16 Provision for earthing
17 Resistance to heat, fire and tracking
18 Terminals and connections for external wiring
Annex ZA (normative) Normative References to international
publications with their corresponding European
publications
Deals with track systems with two poles or more for connecting luminaires to electrical supply, either of rated voltage of 440 V or less between poles with provision for earthing (class I) and rated current of 16 A or less per conductor, or rated SELV of 25 V or less without provision for earthing (class III) and rated current of 25 A or less per conductor. Track systems may also give mechanical support of luminaires. Covers track systems for interior use for mounting on, or flush with, or suspended from ceilings and walls, but not for environments where special conditions apply, such as on ships, vehicles, etc, and in hazardous environments, where explosions could happen.
Committee |
CPL/34/4
|
DevelopmentNote |
Supersedes 00/242820 DC, 93/216382 DC, 96/212324 DC and 98/201211 DC. (10/2003)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Supersedes |
This standard applies to track systems for ordinary interior use with two or more poles and with provision for earthing (Class 1), with a rated voltage not exceeding 440 V between poles (live conductors), rated frequency not exceeding 60 Hz and a rated current not exceeding 16 A per conductor for the connection of luminaires to the electrical supply.
Standards | Relationship |
UNE-EN 60570:2004 | Identical |
NF EN 60570 : 2003 | Identical |
SN EN 60570 : 2003 | Identical |
NBN EN 60570 : 2003 | Identical |
I.S. EN 60570:2003 | Identical |
DIN EN 60570 : 2004 | Identical |
IEC 60570:2003+AMD1:2017 CSV | Identical |
EN 60570:2003/A1:2018 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60417-2:1999 | Graphical symbols for use on equipment - Part 2: Symbol originals |
IEC 60417-2:1998 | Graphical symbols for use on equipment - Part 2: Symbol originals |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.