6.1 Scope
6.1.1 Normative references
6.2 General test requirements
6.3 Definitions
6.4 Classification of luminaires
6.5 Marking
6.6 Construction
6.7 Creepage distances and clearances
6.8 Provision for earthing
6.9 Terminals
6.10 External and internal wiring
6.11 Protection against electric shock
6.12 Endurance tests and thermal tests
6.13 Resistance to dust and moisture
6.14 Insulation resistance and electric strength
6.15 Resistance to heat, fire and tracking
Annex A (normative) Examples of construction
Annex ZA (normative) Other international publications
quoted in this standard with references of the relevant
European publications
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references
For luminaires with supply voltages and output voltages not exceeding 1000 V for class I and class II luminaires, and 250 V for class 0 luminaires.
Committee |
CPL/34/4
|
DevelopmentNote |
To be read in conjunction with BS EN 60598-1. Supersedes 93/205203 DC, 95/208536 DC and BS 4533-102.6(1990) Also numbered as IEC 60598-2-6. (11/2003)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This section of IEC 598-2 specifies requirements for luminaire with built-in transformers or convertors for filament lamps, with supply voltages and output voltages not exceeding:
1 000 V for class I and class II luminaires and
250 V for class 0 luminaires.
It is to be read in conjunction with those sections of IEC 598-1 to which reference is made.
This section does not apply to class III luminaires.
It is not necessary to use “Safety extra low voltage” (SELV) transformers or (SELV) convertors to comply with the requirements of this section. However, such transformers or convertors may satisfy the functional requirements of this section.
6.1.1 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this section of IEC 598-2. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this section of IEC 598-2 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below.
Members of IEC and ISO maintain registers of currently valid International Standards.
IEC 417:1973, Graphical symbols for use on equipment.
IEC 598-1:1992, Luminaires — Part 1: General requirements and tests.
IEC 742:1983, Isolating transformers and safety isolating transformers — Requirements.
IEC 1046:1993, DC or a.c. supplied electronic step-down convertors for filament lamps — General and safety requirements.
Standards | Relationship |
EN 60598-2-6:1994 | Identical |
EN 60598-2-6:1994/A1:1997 | Identical |
SN EN 60598-2-6 : 1994 AMD 1 1997 | Identical |
UNE-EN 60598-2-6:1996 | Identical |
DIN EN 60598-2-6 : 95 AMD 1 97 | Identical |
I.S. EN 60598-2-6:1995 | Identical |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
BS 6217:1981 | Guide to graphical symbols for use on electrical equipment |