BS EN 60601-2-19 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-19: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFANT INCUBATORS (IEC 60601-2-19:2009)
Hardcopy , PDF
30-12-2021
English
01-01-2009
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME
EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME
EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME
SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Describes safety requirements for INFANT INCUBATORS but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
Committee |
CH/62/4
|
DevelopmentNote |
Supersedes BS 5724-2.119(1991) and 95/560383 DC. (11/2005) Supersedes 06/30154548 DC. (08/2009) 2009 Edition remains current. (03/2012) 2009 Edition Re-issued in February 2017 & incorporates AMD 1 2016. 2009 + A11 2011 Edition remains current and will be withdrawn on 16/12/2019. Supersedes 15/30323100 DC.(02/2017)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 60601-2-19:2009 | Identical |
DIN EN 60601-2-19 : 2017 | Identical |
IEC 60601-2-19:2009+AMD1:2016 CSV | Identical |
UNE-EN 60601-2-19:2010 | Identical |
EN 60601-2-19:2009/A1:2016 | Identical |
SN EN 60601-2-19:2009+A11:2011+A1:2016 | Identical |
BS EN 60601-2-35:1997 | Medical electrical equipment. Particular requirements for safety Specification for blankets, pads and mattresses intended for heating in medical use |
BS 5724-2.35(1997) : 1997 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR BLANKETS, PADS AND MATTRESSES INTENDED FOR HEATING AND MEDICAL USE |
IEC 60601-2-21:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers |
IEC 60601-2-50:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-50: Particular requirementsfor the basic safety and essential performance of infant phototherapy equipment |
ISO 80601-2-56:2017 | Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement |
EN 60601-2-50:2009/A1:2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-50: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFANT PHOTOTHERAPY EQUIPMENT (IEC 60601-2-50:2009/A1:2016) |
IEC 60601-2-20:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transportincubators |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 60601-2-21:2009/A1:2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-21: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFANT RADIANT WARMERS (IEC 60601-2-21:2009/A1:2016) |
EN ISO 80601-2-56:2017 | Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (ISO 80601-2-56:2017) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.