1 Scope and normative references
2 Definitions
3 General requirements
4 General notes on tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Endurance
18 Mechanical strength
19 Threaded parts and connections
20 Creepage distances, clearances and distances through
solid insulation
21 Fire hazard testing
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements - emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements - immunity
27 Abnormal operation
28 Guidance on the use of electronic disconnection
Annexes
Annex H (normative) - Requirements for electronic controls
Annex AA (normative) - Number of cycles for independently
mounted controls for boiler applications
Annex BB (normative) - Requirements for response delay
Annex CC (informative) - Number of cycles for independently
mounted air flow and water flow sensing controls
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements of
EC Directives
Pertains to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications.
Committee |
CPL/72
|
DevelopmentNote |
To be read in conjunction with BS EN 60730-1. Supersedes BS 3955(1986). (03/2002) Supersedes 92/27869 DC & 95/202976 DC (07/2005) Supersedes 04/30115376 DC. (09/2007) Supersedes BS EN 60730-2-16 and BS EN 60730-2-18. Supersedes 03/117957 DC. (05/2010)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This clause of Part 1 is replaced as follows:
1.1 This part of IEC 60730 applies to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air- conditioning and similar applications. EN 60730-2-1 is not applicable to electrical water level sensing controls of the float or electrode-sensor type.
Examples are water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications.
1.1.1 This standard applies to the inherent safety, to the operating values, operating sequences where such are associated with equipment protection, and to the testing of automatic electrical air flow, water flow and water level sensing controls used in, or in association with, household and similar equipment.
This standard is also applicable to controls for appliances within the scope of IEC 60335-1 and IEC 60364-7-702.
Automatic electrical air flow, water flow and water level sensing controls for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
This standard is also applicable to individual controls utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs.
This standard is not applicable to pressure-operated air flow, water flow and water level sensing controls, requirements for which are contained in IEC 60730-2-61).
This standard does not apply to air flow, water flow and water level sensing controls designed exclusively for industrial applications.
Throughout this standard, the word \'equipment\' means \'appliance and equipment\'.
1.1.2 This standard applies to automatic electrical controls, mechanically or electrically operated, responsive to or controlling air flow, water flow and water level.
1.1.3 This standard contains requirements for electrical features of air flow, water flow and water level sensing controls and requirements for mechanical features that may affect their intended operation and electrical safety.
1.1.4 This standard applies to manual controls when such are electrically and/or mechanically integral with air flow, water flow and water level sensing controls.
Requirements for manual switches not forming part of an automatic control are contained in IEC 60669 and IEC 61058-1.
1.1.5 In general, these air flow, water flow and water level sensing controls are integrated or incorporated with the equipment or are intended to be integrated or incorporated in or on the equipment. This standard also covers controls when they are independently mounted or of inline cord construction.
1.2 This standard applies to controls with a rated voltage not exceeding 690 V and a rated current not exceeding 63 A.
1.3 This standard takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply.
1.4 This standard applies also to controls incorporating electronic devices, requirements for which are contained in Annex H.
This standard applies also to controls using NTC and PTC thermistors, requirements for which are contained in Annex J.
1.5 Normative references
This subclause of Part 1 is applicable except as follows:
Addition:
IEC 60364-7-702, Electrical installation of buildings – Part 7: Requirements for special installations or locations – Section 702: Swimming pools and other basins
IEC 60669 (all parts), Switches for household and similar fixed-electrical installations
Standards | Relationship |
DIN EN 60730-2-15 : 2011 | Identical |
SN EN 60730-2-15 : 1995 AMD 11 2005 | Identical |
NF EN 60730-2-15 : 2010 | Identical |
EN 60730-2-15:2010 | Identical |
I.S. EN 60730-2-15:2010 | Identical |
UNE-EN 60730-2-15:2011 | Identical |
BS PAS 33(1999) : 1999 | SPECIFICATION FOR THE DESIGN, INSTALLATION AND COMMISSIONING OF GAS FIRED CENTRAL HEATING SYSTEMS IN DOMESTIC PREMISES |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
HD 384.7.702 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SWIMMING POOLS AND OTHER BASINS |
IEC 60364-7-702:2010 | Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.