BS EN 60811-2-1:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests
Hardcopy , PDF
31-07-2012
English
28-08-2002
Foreword
1 General
1.1 Scope
1.2 Normative references
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Ozone resistance test
8.1 Test method
8.2 Determination of ozone concentration
9 Hot set test
9.1 Sampling and preparation of test pieces and
determination of their cross-sectional area
9.2 Test apparatus
9.3 Procedure
9.4 Evaluation of results
10 Mineral oil immersion test for sheaths
10.1 Sampling and preparation of the test pieces
10.2 Determination of the cross-sectional area of the
test piece
10.3 Oil to be used
10.4 Procedure
10.5 Determination of mechanical properties
10.6 Expression of results
Annex ZA (normative) Normative references to international publications
with their corresponding European publications
Specifies test methods to be used for testing polymeric insulating and sheathing materials of electric and optical cables used for power distribution and telecommunications, including cables used on ships
Committee |
GEL/20
|
DevelopmentNote |
Supersedes 96/213294 DC, 99/240640 DC and BS 6469-2.1(1992) Also numbered as IEC 60811-2-1 (09/2002)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 60811-2-1:1997 | Identical |
UNE-EN 60811-2-1:1999 | Identical |
SN EN 60811-2-1 : 1998 AMD 1 2001 | Identical |
NF EN 60811-2-1 : 99 AMD 1 2002 | Identical |
EN 60811-2-1 : 98 AMD 1 2001 | Identical |
DIN EN 60811-2-1 : 2002 | Identical |
BS 7870-5:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
11/30214073 DC : 0 | BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
BS 7870-8.5:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath |
BS 7870-4.11:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 33 kV lead sheathed cables - Single core 33 kV lead sheathed cables |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
BS 7870-4.10(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-4.11(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-4.20(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-4.10:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 11 kV and 33 kV cables - Single core 11 kV and 33 kV cables |
11/30219798 DC : 0 | BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION |
BS 6622:1999 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV |
BS 7655-0:1997 | Specification for insulating and sheathing materials for cables General introduction |
BS 7835:2000 | Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV having low emission of smoke and corrosive gases when affected by fire |
BS 6622:1991 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V |
BS 7655-0:2006 | Specification for insulating and sheathing materials for cables General introduction |
BS 7870-5:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
BS 7912:2001 | Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7870-7.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring |
11/30214077 DC : 0 | BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES |
BS 7870-8.6:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors |
BS 7870-4.13:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 33 kV copper wire/foil sheath cables - Section 4.13: Single core 33 kV copper wire/foil sheath cables |
BS 7870-2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
BS 7870-4.12:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 11 kV copper foil sheath cables - Section 4.12: single core 11 kV copper foil sheath cables |
11/30214075 DC : 0 | BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES |
BS 6469-99.1(1992) : 1992 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - PART 99: TEST METHODS USED IN THE UNITED KINGDOM BUT NOT SPECIFIED IN BS EN 60811 - SECTION 99.1: NON-ELECTRICAL TESTS |
BS 7870-4.20:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Three-core 11 kV cables - Three core 11 kV cables |
BS 7870-7.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring |
BS 7870-8.3:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance - Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
EN 60811-1-1:1995/A1:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES |
ISO 1817:2015 | Rubber, vulcanized or thermoplastic Determination of the effect of liquids |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.