• BS EN 60811-2-1:1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-07-2012

    Language(s):  English

    Published date:  28-08-2002

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 General
       1.1 Scope
       1.2 Normative references
    2 Test values
    3 Applicability
    4 Type tests and other tests
    5 Pre-conditioning
    6 Test temperature
    7 Median value
    8 Ozone resistance test
       8.1 Test method
       8.2 Determination of ozone concentration
    9 Hot set test
       9.1 Sampling and preparation of test pieces and
            determination of their cross-sectional area
       9.2 Test apparatus
       9.3 Procedure
       9.4 Evaluation of results
    10 Mineral oil immersion test for sheaths
       10.1 Sampling and preparation of the test pieces
       10.2 Determination of the cross-sectional area of the
            test piece
       10.3 Oil to be used
       10.4 Procedure
       10.5 Determination of mechanical properties
       10.6 Expression of results
    Annex ZA (normative) Normative references to international publications
             with their corresponding European publications

    Abstract - (Show below) - (Hide below)

    Specifies test methods to be used for testing polymeric insulating and sheathing materials of electric and optical cables used for power distribution and telecommunications, including cables used on ships

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20
    Development Note Supersedes 96/213294 DC, 99/240640 DC and BS 6469-2.1(1992) Also numbered as IEC 60811-2-1 (09/2002)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7870-5:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
    11/30214073 DC : 0 BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES
    11/30214055 DC : 0 BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL
    BS 7870-8.5:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath
    BS 7870-4.11:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 33 kV lead sheathed cables - Single core 33 kV lead sheathed cables
    BS 7870-1:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities General
    BS 7870-4.10(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620)
    BS 7870-4.11(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620)
    BS 7870-4.20(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620)
    BS 7870-4.10:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 11 kV and 33 kV cables - Single core 11 kV and 33 kV cables
    11/30219798 DC : 0 BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION
    BS 6622:1999 Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV
    BS 7655-0:1997 Specification for insulating and sheathing materials for cables General introduction
    BS 7835:2000 Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV having low emission of smoke and corrosive gases when affected by fire
    BS 6622:1991 Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V
    BS 7655-0:2006 Specification for insulating and sheathing materials for cables General introduction
    BS 7870-5:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
    BS 7912:2001 Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (Um=72.5 kV) to 132kV (Um=145kV). Requirements and test methods
    12/30244367 DC : 0 BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
    BS 7870-7.1:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring
    11/30214077 DC : 0 BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES
    BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors
    BS 7870-4.13:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 33 kV copper wire/foil sheath cables - Section 4.13: Single core 33 kV copper wire/foil sheath cables
    BS 7870-2:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test
    BS 7870-4.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single core 11 kV copper foil sheath cables - Section 4.12: single core 11 kV copper foil sheath cables
    11/30214075 DC : 0 BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES
    BS 6469-99.1(1992) : 1992 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - PART 99: TEST METHODS USED IN THE UNITED KINGDOM BUT NOT SPECIFIED IN BS EN 60811 - SECTION 99.1: NON-ELECTRICAL TESTS
    BS 7870-4.20:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Three-core 11 kV cables - Three core 11 kV cables
    BS 7870-7.2:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring
    BS 7870-8.3:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance - Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
    EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
    IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
    ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective