• Shopping Cart
    There are no items in your cart

BS EN 60811-512:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Methods specific to polyethylene and polypropylene compounds. Tensile strength and elongation at break after conditioning at elevated temperature

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2012

€140.23
Excluding VAT

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Explains the procedure for testing tensile strength and elongation at break after conditioning at elevated temperature.

Committee
GEL/20/17
DevelopmentNote
Together with BS EN 60811-100, BS EN 60811-407, BS EN 60811-408, BS EN 60811-410, BS EN 60811-510, BS EN 60811-513, it supersedes BS EN 60811-4-2. Supersedes 09/30193063 DC. To be read in conjunction with BS EN 60811-100. (08/2012)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 60811-512:2012 describes the procedure for testing tensile strength and elongation at break after conditioning at elevated temperature. It is specific to polyethylene and polypropylene compounds. This test is intended for samples from filled cables, of polyolefin insulations with a wall thickness of more than 0,8 mm and for polyolefin sheaths in direct contact with filling compound. IEC 60811-512:2012 cancels and replaces Clause 8 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.

This publication is to be read in conjunction with IEC 60811-100:2012.

Standards Relationship
EN 60811-512:2012 Identical
IEC 60811-512:2012 Identical

IEC 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-601:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
IEC 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.