• Shopping Cart
    There are no items in your cart

BS EN 60831-1:2014

Current

Current

The latest, up-to-date edition.

Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V General. Performance, testing and rating. Safety requirements. Guide for installation and operation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2014

€254.76
Excluding VAT

Committee
W/-
DevelopmentNote
Together with BS EN 60831-2, BS EN 60871-1, BS EN 60871-4, BS EN 60931-1, BS EN 60931-2 and BS EN 60931-3 it supersedes BS 1650(1971). (04/2000) Supersedes 95/208950 DC. (03/2004) Supersedes 98/232733 DC. (05/2005) 2014 Version incorporates corrigendum. Supersedes 11/30243422 DC. (07/2014)
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 60831-1:2014 is available as IEC 60831-1:2014 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60831-1:2014 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60831 also applies to capacitors intended for use in power filter circuits. Additional definitions, requirements, and tests for power filter capacitors are given in Annex A. The object of this part of IEC 60831 is to:
- formulate uniform rules regarding performances, testing and rating;
- formulate specific safety rules;
- provide a guide for installation and operation. This third edition cancels and replaces the second edition published in 1996 and Amendment 1:2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Updating of the normative references;
- Test conditions have been clarified;
- Thermal stability test has been clarified;
- Maximum permissible voltage and current have been clarified;
- The protection of the environment has been amended with safety concerns and plastic quality requirements.
The contents of the corrigendum of May 2014 have been included in this copy.

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
EN 61000-4-1:2007 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61048:2006+AMD1:2015 CSV Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements
EN 60831-2:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC TR 60996:1989 Method for verifying accuracy of tan delta measurements applicable to capacitors
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
IEC 60721-2-6:1990 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock
IEC 60831-2:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test
IEC 60273:1990 Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
IEC 60358-1:2012 Coupling capacitors and capacitor dividers - Part 1: General rules
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 60252-1:2010+AMD1:2013 CSV AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60143-3:2015 Series capacitors for power systems - Part 3: Internal fuses
EN 60695-2-12:2010/A1:2014 FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014)
IEC 60143-4:2010 Series capacitors for power systems - Part 4: Thyristor controlled series capacitors
IEC 60110-1:1998 Power capacitors for induction heating installations - Part 1: General
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.