BS EN 60976 : 2008

Current

Current

The latest, up-to-date edition.

MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2008

€348.24
Excluding VAT

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
   4.1 General
   4.2 Transport and storage
   4.3 Power supply
5 General information to the USER
   5.1 Functional performance characteristics
   5.2 Available nominal energies and ABSORBED DOSE RATES
   5.3 Available RADIATION FIELDS
   5.4 NORMAL TREATMENT DISTANCE
   5.5 Available WEDGE X-RAY FIELDS
   5.6 Available flattening FILTERS
   5.7 Availability
   5.8 Influencing quantities
   5.9 Maintenance
   5.10 Presentation
   5.11 Dimensions, clearances, within the RADIATION HEAD, and
        in the region RADIATION HEAD to ISOCENTRE, of BEAM
        LIMITING DEVICES
   5.12 IMRT
6 Standardized test conditions
   6.1 General
   6.2 Angle settings
   6.3 Properties and positioning of the PHANTOM
   6.4 Positioning of measuring points
   6.5 RADIATION DETECTORS
   6.6 STANDARD MEASUREMENT DEPTHS
   6.7 RADIATION FIELDS
   6.8 Adjustments during test
   6.9 Use of RADIOGRAPHIC FILM or alternative imaging method
7 DOSE MONITORING SYSTEM
   7.1 General
   7.2 Reproducibility
   7.3 Proportionality
   7.4 Dependence on angular positions
   7.5 Dependence on GANTRY rotation
   7.6 Dependence on the shape of the RADIATION FIELD
   7.7 Stability of calibration
   7.8 Stability in MOVING BEAM RADIOTHERAPY
8 Depth ABSORBED DOSE characteristics
   8.1 X-RADIATION
   8.2 ELECTRON RADIATION
9 Uniformity of RADIATION FIELDS
   9.1 X-RADIATION
   9.2 ELECTRON RADIATION
   9.3 PENUMBRA of RADIATION FIELDS
10 Indication of RADIATION FIELDS
   10.1 X-RADIATION
   10.2 ELECTRON RADIATION
   10.3 Geometry and motion speeds of adjustable BLDs for
        X-RADIATION and ELECTRON RADIATION
   10.4 Illuminance and PENUMBRA of the LIGHT FIELD
11 Indication of the RADIATION BEAM AXIS
   11.1 General
   11.2 Indication on entry to the PATIENT
   11.3 Indication on exit from the PATIENT
12 ISOCENTRE
   12.1 Displacement of the RADIATION BEAM AXIS from the
        ISOCENTRE
   12.2 Indication of the ISOCENTRE
13 Indication of distance along the RADIATION BEAM AXIS
   13.1 Indicating device
   13.2 Additional indicating device for equipment with
        variable distance between RADIATION SOURCE and
        ISOCENTRE and for non-isocentric equipment
14 Zero position of rotational scales
   14.1 General
   14.2 Information to the USER
   14.3 Tests
15 Congruence of opposed RADIATION FIELDS
   15.1 Information to the USER
   15.2 Test
16 Movements of the PATIENT table
   16.1 General
   16.2 Vertical movement of the table
   16.3 ISOCENTRIC rotation of the table
   16.4 Parallelism of table rotational axes
   16.5 Rigidity of the table
17 ELECTRONIC IMAGING DEVICE (e.g. EPID)
   17.1 Information to the USER
   17.2 Tests
Annex A (informative) Format for presentation of functional
        performances values
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Index of defined terms

Defines measurements and test procedures to be performed by the MANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR.

Committee
CH/62/3
DevelopmentNote
Supersedes 85/53310 DC and 98/563592 DC. Renumbers and supersedes BS 5724-3.1(1990). (10/2001) 2001 version incorporates amendment 10622 to BS 5724-3.1(1990). (01/2006)
DocumentType
Standard
Pages
102
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
NF EN 60976 : 2008 Identical
SN EN 60976 : 1999 AMD 1 2000 Identical
DIN EN 60976:2011-02 Identical
I.S. EN 60976:2007 Identical
IEC 60976:2007 Identical
EN 60976:2007 Identical
UNE-EN 60976:2008 Identical
NBN EN 60976 : 2008 Identical

EN 61217:2012 Radiotherapy equipment - Coordinates, movements and scales
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC TR 60977:2008 Medical electrical equipment - Medical electron accelerators - Guidelines for functional performance characteristics
IEC 60580:2000 Medical electrical equipment - Dose area product meters
IEC 60601-2-1:2009+AMD1:2014 CSV Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
IEC 61217:2011 Radiotherapy equipment - Coordinates, movements and scales
EN 60580:2000 Medical electrical equipment - Dose area product meters
EN 60601-2-1:2015 Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV