• BS EN 61000-4-16:1998+A2:2011

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromagnetic compatibility (EMC) Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-01-2016

    Language(s):  English

    Published date:  30-06-2011

    Publisher:  British Standards Institution

    Add To Cart

    Scope - (Show below) - (Hide below)

    This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz.

    The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports.

    This standard defines

    • test voltage and current waveform;

    • range of test levels;

    • test equipment;

    • test set-up;

    • test procedures.

    For some types of ports, for example ports intended to be used with highly balanced lines, additional test provisions may be established by product committee specifications.

    The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.

    The disturbances produced by 400 Hz mains systems are not included in the scope of this standard.

    Actual interference due to these disturbance phenomena is relatively rare, except in industrial plants. Product Committees should therefore consider whether there is a justification for applying this standard in their Product/Product Family standards (see also clause 3).

    This test is not relevant for equipment ports intended to be connected to short cables, having a length less than 20 m or less.

    The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC 61000-4-13.

    The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC 61000-4-6.

    Text deleted

    General Product Information - (Show below) - (Hide below)

    Committee GEL/210
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective