BS EN 61009-1 : 2012
Current
The latest, up-to-date edition.
RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES
Hardcopy , PDF
English
01-01-2012
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics of RCBOs
6 Marking and other product information
7 Standard conditions for operation in
service and for installation
8 Requirements for construction and operation
9 Tests
Annex A (normative) - Test sequence and number
of samples to be submitted for certification
purposes
Annex B (normative) - Determination of clearances
and creepage distances
Annex C (normative) - Arrangement for the detection
of the emission of ionized gases during
short-circuit tests
Annex D (normative) - Routine tests
Annex E (normative) - Special requirements for auxiliary
circuits for safety extra-low voltage
Annex F (normative) - Coordination between RCBOs
and separate fuses associated in the same circuit
Annex G (normative) - Additional requirements and
tests for RCBOs consisting of a circuit-breaker
and a residual current unit designed for assembly
on site
Annex H (informative) - Void
Annex IA (informative) - Methods for determination of
short-circuit power-factor
Annex IB (informative) - Glossary of symbols
Annex IC (informative) - Examples of terminals
Annex IE (informative) - Follow-up testing programme
for RCBOs
Annex J (normative) - Particular requirements for RCBOs
with screwless type terminals for external copper
conductors
Annex K (normative) - Particular requirements for RCBOs
with flat quick-connect terminations
Bibliography
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
Annex ZB (normative) - Special national conditions
Annex ZC (informative) - A-deviations
Annex ZD (normative) - Classification of RCBOs Type B
and C up to and including 63A into energy limiting
classes
Annex ZXX (Informative) - List of clauses that require
retesting
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to residual current operated circuit-breakers with integral overcurrent protection functionally independent of or functionally dependent on line voltage for household and similar uses (hereafter referred to as RCBOs) for rated voltages exceeding 440 V a.c. and rated currents not exceeding 125 A for fixed installations and rated short-circuit capacities not exceeding 25000 A.
| Committee |
PEL/23/1
|
| DevelopmentNote |
Supersedes 88/22488 DC, 97/207510 DC, 97/207744 DC, 97/207745 DC, 97/208714 DC, 01/206499 DC, 99/205378 DC, 07/30162127 DC, 08/30176730 DC, 10/30237877 DC, 07/30169774 DC, 12/30272112 DC. 2004 version along with its amendments remains current. 2004 + A14 2012, 2012 & 2012 + A2 2014 Editions remains active & will be withdrawn on 18/06/2017, 04/08/2017 & 06/07/2018, respectively. Supersedes 15/30321815 DC (10/2015) 2012 + A11 2015 Edition remains active & will be withdrawn on 11/02/2019. 2012 Edition Re-Issued in April 2016 & incorporates AMD 12 2016.(05/2016)
|
| DocumentType |
Standard
|
| Pages |
186
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
|
| Standards | Relationship |
| NBN EN 61009-1 : 2013 AMD 3 2015 | Identical |
| DIN EN 61009-1 : 2016 | Identical |
| I.S. EN 61009-1:2012 | Identical |
| NF EN 61009-1 : 2013 AMD 12 2016 | Identical |
| NEN EN 61009-1 : 1995 AMD 11 1995 | Identical |
| EN 61009-1:2012 | Equivalent |
| UNE-EN 61009-1:2013 | Identical |