• BS EN 61102:1994

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz

    Available format(s):  Hardcopy, PDF

    Superseded date:  30-05-2008

    Language(s):  English

    Published date:  15-04-1994

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Cooperating organizations
    National foreword
    Foreword
    Introduction
    1. Scope
    2. Normative references
    3. Definitions
    4. List of symbols
    5. Measurement requirements
    5.1 Requirements for hydrophones and amplifiers
    5.1.1 General
    5.1.2 Sensitivity of a hydrophone
    5.1.3 Directional response of a hydrophone
    5.1.4 Effective radius of a hydrophone active element
    5.1.5 Choice of the size of a hydrophone active element
    5.1.6 Bandwidth
    5.1.7 Linearity
    5.1.8 Hydrophone signal amplifier
    5.2 Requirements for positioning systems and water
           baths
    5.2.1 Positioning systems
    5.2.2 Water bath
    5.3 Requirements for measurement systems
    5.4 Recommendations for ultrasonic equipment being
           characterised
    6. Specification of performance for hydrophones and
           amplifiers
    6.1 Sensitivity
    6.2 Effective radius
    6.3 Hydrophone linearity
    6.4 Hydrophone amplifiers
    7. Measurement procedures
    7.1 Preparation and alignment
    7.1.1 Preparation
    7.1.2 Aligning a hydrophone
    7.1.3 Aligning an ultrasonic transducer and hydrophone
    8. Beam characterisation
    8.1 Primary pressure parameters
    8.1.1 Peak-positive and peak-negative acoustic pressure
    8.1.2 Pulse acoustic pressure
    8.1.3 Spatial-peak pulse acoustic pressure
    8.1.4 Spatial-peak r.m.s. acoustic pressure
    8.1.5 Beam-average pulse acoustic pressure
    8.1.6 Beam-average r.m.s. acoustic pressure
    8.1.7 Spatial-average pulse acoustic pressure
    8.1.8 Spatial-average r.m.s. acoustic pressure
    8.1.9 Nonlinear propagation parameter
    8.2 Derived intensity parameters
    8.3 Derived pulse-intensity integral parameters
    9. Acoustic output specification and labelling
    Annexes
    A. (informative)
    A.1 Hydrophones
    A.1.1 Electrical loading considerations
    A.1.2 Hydrophone signal amplifier
    A.1.3 Alignment of hydrophones
    A.1.4 Types of hydrophone
    A.1.4.1 Ceramic probe hydrophones
    A.1.4.2 PVDF probe hydrophones
    A.1.4.3 PVDF membrane hydrophones
    A.1.4.4 Relative performance of different types
    A.1.5 Typical specification data for hydrophones
    B. (informative)
    B.1 Acoustic pressure and intensity
    C. (informative)
    C.1 Transducer and hydrophone positioning systems
    D. (informative)
    Rationale
    Bibliography
    Figures
    Annex ZA (normative) Other international publications
    quoted in this standard with the references of the
    relevant European publications
    National annex NA (informative) Committees responsible
    National annex NB (informative) Cross-references

    Abstract - (Show below) - (Hide below)

    Defines acoustic parameters, derived intensity parameters and measurement conditions when using calibrated piezoelectric hydrophones in liquids of acoustic fields.

    General Product Information - (Show below) - (Hide below)

    Committee EPL/100
    Development Note Also numbered as IEC 61102. Supersedes 88/29416 DC. (12/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 61220:1995 Ultrasonics. Fields. Guidance for the measurement and characterization of ultrasonic fields generated by medical ultrasonic equipment using hydrophones in the frequency range 0.5 MHz to 15 MHz
    BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting
    BS EN 61206:1995 Ultrasonics. Continuous-wave Doppler systems. Test procedures

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 7041:1989 Specification for characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz
    IEC TR 60854:1986 Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment
    IEC 60469-1:1987 Pulse techniques and apparatus. Part 1: Pulse terms and definitions
    IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
    IEC 60866:1987 Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective