BS EN 61189-2-721:2015
Current
The latest, up-to-date edition.
Test methods for electrical materials, printed boards and other interconnection structures and assemblies Test methods for materials for interconnection structures. Measurement of relative permittivity and loss tangent for copper clad laminate at microwave frequency using split post dielectric resonator
Hardcopy , PDF
English
30-06-2015
FOREWORD
1 Scope
2 Test specimens
3 Equipment/apparatus
4 Procedure
5 Report
6 Additional information
Annex A (informative) - Example of test fixture and
test result
Annex B (informative) - Additional information on
K[varepsilon](varepsilon[gamma],h) and rho[es]
Bibliography
Defines way to determine the relative permittivity (varepsilon[gamma]) and loss tangent (tan[delta]) (also called dielectric constant (Dk) and dissipation factor (Df)) of copper clad laminates at microwave frequencies (from 1,1 GHz to 20 GHz) using a split post dielectric resonator (SPDR).
| Committee |
EPL/501
|
| DevelopmentNote |
Supersedes 13/30287604 DC. (07/2015)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
IEC 61189-2-721:2015 outlines a way to determine the relative permittivity and loss tangent (also called dielectric constant and dissipation factor) of copper clad laminates at microwave frequencies (from 1,1 GHz to 20 GHz) using a split post dielectric resonator (SPDR). IEC 61189-2-721:2015 is applicable to copper clad laminates and dielectric base materials.
| Standards | Relationship |
| IEC 61189-2-721:2015 | Identical |
| EN 61189-2-721:2015 | Identical |
| I.S. EN 61189-2-721:2015 | Equivalent |
| EN 60904-2:2007 | Identical |