BS EN 61223-2-6:2007
Current
The latest, up-to-date edition.
Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
Hardcopy , PDF
English
30-11-2007
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 General aspects of CONSTANCY TESTS
4.1 Preconditions
4.2 General conditions affecting test procedures
4.3 Establishment of BASELINE VALUES
4.4 Identification of equipment, instrumentation and test
conditions
4.5 Scope of the CONSTANCY TESTS
4.6 Test equipment, including PHANTOMS and TEST DEVICES
4.7 Frequency of CONSTANCY TESTS
5 Test methods for CT SCANNERS
5.1 Positioning of the PATIENT SUPPORT
5.2 PATIENT positioning accuracy
5.3 TOMOGRAPHIC SECTION THICKNESS
5.4 Dose
5.5 NOISE, UNIFORMITY AND MEAN CT NUMBERS
5.6 SPATIAL RESOLUTION
Annex A (informative) - Guidance on action to be taken
Annex B (informative) - Alternate test methods for SPATIAL RESOLUTION
Annex C (informative) - TOMOGRAPHIC SECTION THICKNESS for helical
scanning
Annex D (informative) - Visual method for LOW CONTRAST RESOLUTION
Bibliography
Index of terms
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Gives assistance in performing CONSTANCY TESTS on a CT SCANNER. It applies to those components of CT SCANNERS which influence the image quality, PATIENT dose and positioning.
| Committee |
CH/62/2
|
| DevelopmentNote |
Supersedes 93/504902 DC (11/2005) Supersedes 04/30124942 DC & BS 7725-2.6(1995). (11/2007)
|
| DocumentType |
Standard
|
| Pages |
38
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of IEC 61223 provides assistance in performing constancy tests on a CT scanner. It applies to those components of CT scanners which influence the image quality, patient dose and positioning. This standard - defines the essential parameters which describe the performance of CT scanners with regard to image quality, patient dose and positioning; the list of parameters to be tested can be found in section 4.5; - defines the methods of testing the essential parameters; - provides criteria to be applied in the evaluation of data for compliance with the tolerances of the parameters specified by the accompanying documents and with respect to baseline values. These methods rely on non-invasive measurements, using appropriate test equipment, performed to ensure that the functional performance of equipment meets established criteria or to enable the early recognition of changes in the properties of components of the equipment. The aim is to verify compliance with specifications affecting the image quality, patient dose and patient positioning.
| Standards | Relationship |
| EN 50289-4-11:2002 | Identical |
| IEC 61223-2-6:2006 | Identical |
| EN 61223-2-6:2007 | Identical |
| DIN EN 61223-2-6:2008-12 | Identical |
| I.S. EN 61223-2-6:2007 | Identical |
| NF EN 61223-2-6 : 2007 | Identical |
| UNE-EN 61223-2-6:2008 | Identical |