BS EN 61481-2:2014
Current
The latest, up-to-date edition.
Live working. Phase comparators Resistive type to be used for voltages from 1 kV to 36 kV a.c.
Hardcopy , PDF
English
31-01-2015
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests
6 Conformity assessment of phase comparators
having completed the production phase
7 Modifications
Annex A (normative) - Instructions for use
Annex B (normative) - Suitable for live working; double
triangle (IEC 60417-5216(2002-10))
Annex C (normative) - Chronology of type tests
Annex D (normative) - Classification of defects and tests
to be allocated
Annex E (informative) - Information and guidelines on the
use of the limit mark and of a contact electrode
extension
Annex F (informative) - Rationale for the classification of
defects
Annex G (informative) - In-service care
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to portable phase comparators of resistive type to be used on electrical systems for voltages from 1 kV a.c. to 36 kV a.c. and frequencies of 50 Hz and/or 60 Hz.
| Committee |
PEL/78
|
| DevelopmentNote |
Together with BS EN 61481-1, it supersedes BS EN 61481. Supersedes 13/30267625 DC. (01/2015)
|
| DocumentType |
Standard
|
| Pages |
82
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of IEC61481 is applicable to portable phase comparators of resistive type to be used on electrical systems for voltages from 1kV a.c. to 36kV a.c. and frequencies of 50Hz and/or 60Hz. This standard is applicable to phase comparators of resistive type used in contact with the bare conductive parts to be compared: as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. NOTE Some parts such as the contact electrode or the insulating element of a phase comparator as a complete device may be dismantled. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see AnnexA). A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For examplea device designed to be also used as a voltage detector is not covered by this standard (see AnnexA). Products designed and manufactured according to this standard contribute to the safety of the users provided they are used by persons trained for the work, in accordance with the hot stick working method and the instructions for use. Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.
| Standards | Relationship |
| EN 61481-2:2014 | Identical |
| IEC 61481-2:2014 | Identical |
| I.S. EN 61481-2:2014 | Equivalent |