BS EN 61558-2-19:2001
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Safety of power transformers, power supply units and similar Particular requirements for perturbation attenuation transformers
Hardcopy , PDF
20-04-2012
English
15-06-2001
Clause
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and other information
9 Protection against accessibility to hazardous
live parts
10 Change of input voltage setting
11 Output voltage and output current under load
12 No-load output voltage
13 Short-circuit voltage
14 Heating
15 Short-circuit and overload protection
16 Mechanical strength
17 Protection against harmful ingress of dust, solid
objects and moisture
18 Insulation resistance and dielectric strength
19 Construction
20 Components
21 Internal wiring
22 Supply connection and other external flexible cords
23 Terminals for external conductors
24 Provision for protective earthing
25 Screws and connections
26 Creepage distances, clearances and distances through
insulation
27 Resistance to heat, abnormal heat, fire and tracking
28 Resistance to rusting
29 Annexes
Applies to stationary or portable, single-phase or poly-phase, air cooled (natural or forced) isolating or safety transformers.
Committee |
PEL/96
|
DevelopmentNote |
Also numbered as IEC 61558-2-19. (05/2001) Supersedes 98/232713 DC. (01/2006)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This International Standard deals with all aspects of safety such as electrical, thermal and mechanical. This part 2-19 of IEC 61558 applies to stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), independent or associated, isolating or safety isolating transformers, having a rated supply voltage not exceeding 1 000 V a.c., a rated frequency not exceeding 500 Hz, a rated output not exceeding 10 kVA. Perturbation attenuation transformers are intended to the supply of office machines and the like and have a mid-point lead out in the output circuit in order to attenuate mains borne disturbances. In addition, double or reinforced insulation between circuits required by the installation rules or by the appliance specification is fulfilled by using this transformer. This part 2-19 is intended to be used in conjunction with IEC 61558-1 It has the status of a group safety publication in accordance with IEC Guide 104.
Standards | Relationship |
EN 61558-2-19 : 2001 | Identical |
DIN EN 61558-2-19 : 2001 | Identical |
I.S. EN 61558-2-19:2001 | Identical |
SN EN 61558-2-19 : 2001 | Identical |
NF EN 61558-2-19 : 2001 | Identical |
UNE-EN 61558-2-19:2002 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.