BS EN 61643-311:2013
Current
The latest, up-to-date edition.
Components for low-voltage surge protective devices Performance requirements and test circuits for gas discharge tubes (GDT)
Hardcopy , PDF
English
30-09-2013
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Service conditions
5 Mechanical requirements and materials
6 General
7 Electrical requirements
8 Test and measurement procedures and circuits
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1000 V (r.m.s.) a.c. and 1500 V d.c..
| Committee |
PEL/37
|
| DevelopmentNote |
Supersedes 98/203339 DC. (05/2002) Supersedes 10/30184592 DC. (10/2013)
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
IEC 61643-311:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c..They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard contains a series of test criteria, test methods and test circuits for determining the electrical characteristics of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. This second edition of IEC 61643-311 cancels and replaces the first edition published in 2001. It constitutes a technical revision. Specific changes with respect to the previous edition are: Addition of performance values. Key words: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.
| Standards | Relationship |
| I.S. EN 61643-311:2013 | Identical |
| IEC 61643-311:2013 | Identical |
| NF EN 61643-311 : 2014 | Identical |
| NBN EN 61643-311 : 2013 | Identical |
| DIN EN 61643-311:2014-02 | Identical |
| EN 61643-311:2013 | Identical |