• Shopping Cart
    There are no items in your cart

BS EN 61689:2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

Available format(s)

Hardcopy , PDF

Withdrawn date

18-01-2023

Superseded by

BS EN IEC 61689:2022

Language(s)

English

Published date

31-05-2013

€303.84
Excluding VAT

Committee
EPL/87
DevelopmentNote
Supersedes 93/203591 DC. (09/2005) Supersedes 04/30115966 DC. (12/2007) Supersedes 11/30230872 DC. (05/2013)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

IEC 61689:2013 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous wave ultrasound in the frequency range 0,5 MHz to 5 MHz. This standard only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard specifies:
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;
- characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods;
- guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment;
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;
- and acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard. This third edition cancels and replaces the second edition published in 2007. It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- restriction introduced of 0,2 W/cm 2 effective intensity during hydrophone measurements for treatment heads with ka?20, to limit the likelihood of cavitation;
- change in the factor F ac, to determine the effective radiating area, from 1,354 to 1,333;
- and change to SI units for terms and definitions.

This publication is to be read in conjunction with IEC 60601-2-5:2009.

Standards Relationship
DIN EN 61689 : 2013 Identical
NBN EN 61689 : 2013 Identical
IEC 61689:2013 Identical
NF EN 61689 : 2013 Identical
EN 61689:2013 Identical
IEC TR 63084:2017 Identical
UNE-EN 61689:1999 Identical
SN EN 61689 : 1996 Identical
I.S. EN 61689:2013 Identical

IEC 62127-1:2007+AMD1:2013 CSV Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz
IEC 60601-2-5:2009 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
IEC 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60050-802:2011 International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics
IEC 61828:2001 Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
EN 60601-2-5:2015 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
IEC TR 60854:1986 Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment
IEC TR 62781:2012 Ultrasonics - Conditioning of water for ultrasonic measurements
EN 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
IEC 60469-1:1987 Pulse techniques and apparatus. Part 1: Pulse terms and definitions
IEC 60050-801:1994 International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics
IEC 62127-3:2007+AMD1:2013 CSV Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz
IEC 62127-2:2007+AMD1:2013+AMD2:2017 CSV Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz
EN 62127-1:2007/A1:2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.