BS EN 61753-086-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fibre optic interconnecting devices and passive components performance standard Non-connectorised single-mode bidirectional 1490 / 1550 nm downstream 1310 nm upstream WWDM devices for category C. Controlled environment
Hardcopy , PDF
English
31-01-2010
30-04-2025
1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
Annex A (normative) - Sample size
Annex B (informative) - General information for
1490/1550 nm downstream and 1310 nm upstream
PON WWDM devices
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Includes the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1490/1550 nm downstream and 1310 nm upstream wide wavelength division multiplexing (WWDM) passive optical network (PON) device must satisfy in order to be categorized as meeting the requirements of category C (controlled environments).
| Committee |
GEL/86/2
|
| DevelopmentNote |
Supersedes 07/30167615 DC. (01/2010)
|
| DocumentType |
Standard
|
| Pages |
20
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of IEC 61753 contains the minimum initial performance, test and measurement requirements and severities which a fibre optic pigtailed 1 490 / 1 550 nm downstream and 1 310 nm upstream wide wavelength division multiplexing (WWDM) passive optical network (PON) device must satisfy in order to be categorized as meeting the requirements of category C (controlled environments), as defined in Annex A of IEC 61753-1.
Annex B of this standard provides information concerning the function of the 1 490 / 1 550 nm downstream and 1 310 nm upstream WWDM.
| Standards | Relationship |
| IEC 61753-086-2:2009 | Identical |
| EN 61753-086-2:2009 | Identical |
| I.S. EN 61753-086-2:2009 | Equivalent |
| IEC 61340-4-3:2017 | Identical |
| UNE-EN 61753-086-2:2009 | Equivalent |