BS EN 61753-091-3:2004
Current
The latest, up-to-date edition.
Fibre optic interconnecting devices and passive components performance standards. Performance standard Single-mode fibre optic pigtailed style circulators for category U. - Uncontrolled environment
Hardcopy , PDF
English
12-11-2004
1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
5.1 Sample size, sequencing and grouping
5.2 Test details and requirements
Annex A (normative) Sequencing and grouping of tests
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Covers the minimum requirements and severities, which a fibre optic circulator shall satisfy in order to be categorised as meeting the requirements of circulator devices used in uncontrolled environments.
Committee |
GEL/86/2
|
DevelopmentNote |
Supersedes 98/263647 DC. (12/2004)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Contains the minimum requirements and severities which a fibre optic circulator shall satisfy in order to be categorised as meeting the requirements of circulator devices used in uncontrolled environments. The requirements cover non-connectorised single mode circulators for category U - Uncontrolled environments.
Standards | Relationship |
DIN EN 61753-091-3:2005-04 | Identical |
NBN EN 61753-091-3 : 2006 | Identical |
NF EN 61753-091-3 : 2005 | Identical |
EN 61753-091-3:2004 | Identical |
I.S. EN 61753-091-3:2004 | Identical |
IEC 61753-091-3:2004 | Identical |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 60793-1-1:2017 | Optical fibres - Part 1-1: Measurement methods and test procedures - General and guidance |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
IEC 61300-3-5:2000 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-5: Examinations and measurements - Wavelength dependence of attenuation |
IEC 61753-2-1:2000 | Fibre optic interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U - Uncontrolled environment |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-14:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-3-5:2001 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-5: Examinations and measurements - Wavelength dependence of attenuation |
EN 61753-2-1:2000 | Fibre optic interconnecting devices and passive components performance standard - Part 2-1: Fibre optic connectors terminated on single-mode fibre for category U - Uncontrolled environment |
IEC 61300-3-32:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-32: Examinations and measurements - Polarization mode dispersion measurement for passive optical components |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-