• BS EN 62271-102 : 2002

    Current The latest, up-to-date edition.

    HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2002

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 General
    2 Normal and special service conditions
    3 Definitions
    4 Ratings
    5 Design and construction
    6 Type tests
    7 Routine tests
    8 Guide to the selection of disconnectors and earthing
       switches
    9 Information to be given with enquiries, tenders and
       orders
    10 Rules for transport, storage, installation, operation and
       maintenance
    11 Safety
    Annex A (normative) - Design and testing of position
            indicating devices
    Annex B (normative) - Bus-transfer current switching
            by disconnectors
    Annex C (normative) - Induced current switching by
            earthing switches
    Annex D (informative) - Test voltage for the most
            disadvantageous dielectric position of an
            earthing switch during operation
             (temporary approach)
    Annex E (normative) - Special requirements for
            disconnectors and earthing switches
            used in gas-insulated and/or metal-enclosed
            switchgear
    Annex F (normative) - Gas-insulated metal-enclosed
            switchgear for rated voltages 72,5 kV
            and above - Requirements for switching
            of bus-charging currents by disconnectors
    Annex G (normative) - Alternative test methods
            for short-circuit current making test
    Annex H (normative) - Specifi c requirements for
            resistor fitted disconnector in metal-enclosed
            gas insulated switchgear
    Bibliography
    Annex ZA (normative) - Normative references
             to international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Pertains to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1000 V and for service frequencies up to and including 60 Hz.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/17/1
    Development Note To be read in conjunction with BS EN 60694. Supersedes BS EN 60129 and 97/208899 DC. (10/2002) Supersedes BS EN 61129 & BS EN 61259. (09/2003) 2002 Edition along with its corrigendum remains current. Supersedes 08/30185263 DC. (12/2011) 2002 Edition Re-Issued in June 2013 & incorporates AMD 2 2013. Supersedes 10/30228774 DC. (06/2013)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
    EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60265-2:1988 High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above
    IEC 62271-101:2012 High-voltage switchgear and controlgear - Part 101: Synthetic testing
    IEC 60517:1990 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
    IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
    IEC 60865-1:2011 Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods
    IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC TR 62271-305:2009 High-voltage switchgear and controlgear - Part 305: Capacitive current switching capability of air-insulated disconnectors for rated voltages above 52 kV
    IEC 60298:1990 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective