BS EN 62439-1 : 2010
Current
The latest, up-to-date edition.
INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS
Hardcopy , PDF
English
01-01-2010
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, abbreviations, acronyms, and
conventions
4 Conformance requirements (normative)
5 Concepts for high availability automation networks
(informative)
6 Classification of networks (informative)
7 Availability calculations for selected networks
(informative)
8 RSTP for High Availability Networks: configuration
rules, calculation and measurement method for
deterministic recovery time in a ring topology
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Defines: - the common elements and definitions for other parts of the IEC 62439 series; - the conformance test specification (normative); - a classification scheme for network characteristics (informative); - a methodology for estimating network availability (informative); - the configuration rules, calculation and measurement method for a deterministic recovery time in RSTP.
| Committee |
AMT/7
|
| DevelopmentNote |
Together with BS EN 62439-2, BS EN 62439-3, BS EN 62439-4, BS EN 62439-5 and BS EN 62439-6, it supersedes BS EN 62439. Supersedes 08/30193922 DC. (06/2010) 2010 Edition Re-Issued in November 2012 and incorporates AMD 1 2012. Supersedes 10/30238675 DC. (11/2012)
|
| DocumentType |
Standard
|
| Pages |
72
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV | Identical |
| EN 62439-1:2010 | Identical |
| EN 62439-1:2010/A2:2017 | Identical |
| I.S. EN 62439-1:2010 | Equivalent |
| EN 61158-6-10:2014 | Industrial communication networks - Fieldbus specifications - Part 6-10: Application layer protocol specification - Type 10 elements |
| EN 61158-6:2004 | Digital data communication for measurement and control - Fieldbus for use in industrial control systems - Part 6: Application layer protocol specification |
| ISO/IEC 15802-3:1998 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Common specifications — Part 3: Media Access Control (MAC) Bridges |
| IEC 61158-6-10:2014 | Industrial communication networks - Fieldbus specifications - Part 6-10: Application layer protocol specification - Type 10 elements |
| IEC 62439-3:2016 | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
| IEC 62439-4:2010 | Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP) |
| IEC TR 61158-1:2010 | Industrial communication networks - Fieldbus specifications - Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series |
| ISO/IEC 11801:2002 | Information technology — Generic cabling for customer premises |
| ISO/IEC 8802-3:2000 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
| IEEE 802.1Q-2014 | IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks |
| IEEE 802.1D-2004 | IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges |
| ISO/IEC 10731:1994 | Information technology — Open Systems Interconnection — Basic Reference Model — Conventions for the definition of OSI services |
| EN 62439-6:2010 | Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP) |
| IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
| IEC 62439-5:2016 | Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP) |
| IEC 61588:2009 | Precision clock synchronization protocol for networked measurement and control systems |
| EN 62439-4:2010/A1:2012 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 4: CROSS-NETWORK REDUNDANCY PROTOCOL (CRP) (IEC 62439-4:2010/A1:2012) |
| EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
| IEC 62439-6:2010 | Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP) |
| EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
| IEC 62439-2:2016 | Industrial communication networks - High availability automation networks - Part 2: Media Redundancy Protocol (MRP) |
| IEC 62439-7:2011 | Industrial communication networks - High availability automation networks - Part 7: Ring-based Redundancy Protocol (RRP) |
| IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
| CLC/TR 61158-1:2010 | Industrial communication networks - Fieldbus specifications - Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.