• BS EN 62439-3:2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Industrial communication networks. High availability automation networks Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)

    Available format(s):  Hardcopy, PDF

    Superseded date:  16-03-2018

    Language(s):  English

    Published date:  31-10-2012

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions, abbreviations, acronyms,
      and conventions
    4 Parallel Redundancy Protocol (PRP)
    5 High-availability Seamless Redundancy (HSR)
    6 Protocol Implementation Conformance Statement
      (PICS)
    7 PRP/HSR Management Information Base (MIB)
    Annex A (informative) - PRP duplicate discard
            algorithm as pseudo-code
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Pertains to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology.

    Scope - (Show below) - (Hide below)

    IEC 62439-3:2012 specifies two redundancy protocols designed to provide seamless recovery in case of single failure of an inter-bridge link or bridge in the network, which are based on the same scheme: duplication of the LAN, resp. duplication of the transmitted information. This second edition cancels and replaces the first edition published in 2010. It constitutes a technical revision. The main changes with respect to the previous edition are:
    - specification of the interconnection of PRP and HSR networks;
    - introduction of a suffix for PRP frames;
    - clarification and modification of specifications to ensure interoperability;
    - slackening of the specifications to allow different implementations;
    - consideration of clock synchronization according to IEC 61588;
    - introduction of test modes to simplify testing and maintenance.

    This publication is to be read in conjunction with IEC 62439-1:2010.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/65/3
    Development Note Together with BS EN 62439-1, BS EN 62439-2, BS EN 62439-4, BS EN 62439-5 and BS EN 62439-6, it supersedes BS EN 62439. (06/2010) Supersedes 10/30238684 DC. (10/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 62439-1:2010/A2:2017 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS (IEC 62439-1:2010/A2:2016)
    IEC 62439-4:2010 Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP)
    ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
    IEEE 802.1Q-2014 IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks
    IEEE 802.1D-2004 IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges
    EN 62439-6:2010 Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
    IEC 62439-5:2016 Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
    IEC 61588:2009 Precision clock synchronization protocol for networked measurement and control systems
    IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods
    IEC 62439-6:2010 Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
    ISO/IEC 8802-2:1998 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 2: Logical link control
    IEC 62439-2:2016 Industrial communication networks - High availability automation networks - Part 2: Media Redundancy Protocol (MRP)
    IEC 62439-7:2011 Industrial communication networks - High availability automation networks - Part 7: Ring-based Redundancy Protocol (RRP)
    EN 62439-7:2012/AC:2015 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 7: RING-BASED REDUNDANCY PROTOCOL (RRP) (IEC 62439-7:2011)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective