BS EN 62561-2:2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Lightning Protection System Components (LPSC) Requirements for conductors and earth electrodes
Hardcopy , PDF
01-03-2021
English
31-07-2012
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests
6 Electromagnetic compatibility (EMC)
7 Structure and content of the test report
Annex A (normative) - Environmental test for conductors, air
termination rods and earth lead-in rods
Annex B (normative) - Requirements for the cross sectional
area, mechanical and electrical characteristics, tests
to be applied
Annex C (normative) - Requirements for dimensions, mechanical
and electrical characteristics, tests to be applied
Annex D (informative) - Typical example calculation of conductor
resistivity
Annex E (informative) - Typical example of calculation of the
tensile strength of a coated material
Annex F (normative) - Flow chart of tests for air termination
conductors, air termination rods, earth lead-in rods
and down conductors
Annex G (normative) - Flow chart of tests for earth rods
Annex H (normative) - Flow chart of tests of joints for
earth rods
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZB (informative) - Identification and differences of
tests between EN 62561-2:2012 and EN 50164-2:2008
Describes the requirements and tests for: - metallic conductors (other than 'natural' conductors) that form part of the air termination system and down conductors; - metallic earth electrodes that form part of the earth termination system.
Committee |
GEL/81
|
DevelopmentNote |
Supersedes BS EN 50164-2. (07/2012)
|
DocumentType |
Standard
|
Pages |
41
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This part of IEC 62561 specifies the requirements and tests for:
metallic conductors (other than “natural” conductors) that form part of the air termination system and down conductors;
metallic earth electrodes that form part of the earth termination system.
Standards | Relationship |
EN 62561-2:2012 | Identical |
IEC 60695-6-1:2005 | Identical |
IEC 62561-2:2012 | Identical |
EN 60695-6-1:2005 | Identical |
EN 50164-2:2008 | Lightning Protection Components (LPC) - Part 2: Requirements for conductors and earth electrodes |
IEC 60228:2004 | Conductors of insulated cables |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN ISO 6892-1:2016 | Metallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2016) |
EN ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009) |
ISO 6892-1:2016 | Metallic materials Tensile testing Part 1: Method of test at room temperature |
IEC 60468:1974 | Method of measurement of resistivity of metallic materials |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
IEC 62561-1:2017 | Lightning protection system components (LPSC) - Part 1: Requirements for connection components |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN ISO 1460:1994 | Metallic coatings - Hot dip galvanized coatings on ferrous materials - Gravimetric determination of the mass per unit area (ISO 1460:1992) |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
EN 62561-1:2017 | Lightning Protection System Components (LPSC) - Part 1: Requirements for connection components |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 6957:1988 | Copper alloys Ammonia test for stress corrosion resistance |
EN ISO 2178:2016 | Non-magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method (ISO 2178:2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.