• Shopping Cart
    There are no items in your cart

BS EN 673:2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Glass in building. Determination of thermal transmittance (U value). Calculation method

Available format(s)

Hardcopy , PDF

Superseded date

27-11-2024

Superseded by

BS EN 673:2024

Language(s)

English

Published date

31-05-2011

€156.59
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols, dimensionless numbers and
   subscripts
5 Basic formulae
6 Basic material properties
7 External and internal heat transfer coefficients
8 Declared values: standardized boundary
   conditions
9 Expression of the results
10 Test report
Annex A (normative) - Iteration procedure for
        glazing with more than one gas space
Bibliography

Defines a calculation method to determine the thermal transmittance of glazing with flat and parallel surfaces.

Committee
B/520
DevelopmentNote
Supersedes 00/103132 DC & 92/12540 DC (10/2001) Supersedes BS 6993-1(1989) (01/2003) Supersedes 02/103062 DC (05/2003)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This European Standard specifies a calculation method to determine the thermal transmittance of glazing with flat and parallel surfaces.

This European Standard applies to uncoated glass (including glass with structured surfaces, e.g. patterned glass), coated glass and materials not transparent in the far infrared which is the case for soda lime glass products, borosilicate glass and glass ceramic. It applies also to multiple glazing comprising such glasses and/or materials. It does not apply to multiple glazing which include in the gas space sheets or foils that are far infrared transparent. The procedure specified in this European Standard determines the U value1) (thermal transmittance) in the central area of glazing.

The edge effects due to the thermal bridge through the spacer of a sealed glazing unit or through the window frame are not included. Furthermore, energy transfer due to solar radiation is not taken into account. The effects of Georgian and other bars are excluded from the scope of this European Standard.

The standard for the calculation of the overall U value of windows, doors and shutters (see EN ISO 10077-1 [1]) gives normative reference to the U value calculated for the glazing components according to this standard.

For the purpose of product comparison, a vertical position of the glazing is specified. In addition, U values are calculated using the same procedure for other purposes, in particular for predicting:

  • heat loss through glazing;

  • conduction heat gains in summer;

  • condensation on glazing surfaces;

  • the effect of the absorbed solar radiation in determining the solar factor (see Bibliography, [2]).

Reference should be made to [3], [4] and [5] or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard.

A procedure for the determination of emissivity is given in EN 12898.

The rules have been made as simple as possible consistent with accuracy.

Standards Relationship
UNE-EN 673:2011 Identical
NBN EN 673 : 2011 Identical
EN 673:2011 Identical
NS EN 673 : 2011 Identical
NF EN 673 : 2011 Identical
DIN EN 673:2011-04 Identical
I.S. EN 673:2011 Identical
UNI EN 673 : 2011 Identical
SN EN 673 : 2011 Identical
NEN EN 673 : 2011 Identical

17/30350483 DC : 0 BS 6262-1 - GLAZING FOR BUILDINGS - PART 1: GENERAL METHODOLOGY FOR THE SELECTION OF GLAZING
BS 6262-1:2017 Glazing for buildings General methodology for the selection of glazing
BS 6262-2:2005 Glazing for buildings Code of practice for energy, light and sound
BS 6262-1:2005 Glazing for buildings General methodology for the selection of glazing
BS 5516-2:2004 Patent glazing and sloping glazing for buildings Code of practice for sloping glazing

ISO 10211:2017 Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
EN 12898:2001 Glass in building - Determination of the emissivity
EN ISO 13790:2008 Energy performance of buildings - Calculation of energy use for space heating and cooling (ISO 13790:2008)
EN ISO 6946:2017 Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12)
EN ISO 10211:2017 Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017)
EN 674:2011 Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method
ISO 10456:2007 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values
EN 675:2011 Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
ISO 13790:2008 Energy performance of buildings Calculation of energy use for space heating and cooling
EN ISO 10077-1:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.