BS EN 779:2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Particulate air filters for general ventilation. Determination of the filtration performance
Hardcopy , PDF
11-07-2018
BS EN ISO 16890-4:2016
BS EN ISO 16890-2:2016
BS EN ISO 16890-1:2016
BS EN ISO 16890-3:2016
English
30-04-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Requirements
6 Classification
7 Test rig and equipment
8 Qualification of test rig and apparatus
9 Test materials
10 Test procedure for the filter
11 Test method for discharging of filter material
12 Uncertainty calculation of the test results
13 Reporting
Annex A (informative) - Shedding from filters
Annex B (informative) - Commentary
Annex C (informative) - Pressure drop calculation
Annex D (informative) - Example of a completed test report
Bibliography
Defines particulate air filters for general ventilation which are classified according to their performance as measured in this test procedure.
Committee |
MCE/21
|
DevelopmentNote |
Supersedes BS 6540-1(1985) and 99/702573 DC (12/2002) Supersedes 09/30200844 DC. (04/2012) Superseded by BS EN ISO 16890-1, BS EN ISO 16890-2, BS EN ISO 16890-3 and BS EN ISO 16890-4, but remains current and will be withdrawn on 30/06/2018. (03/2017)
|
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This European Standard refers to particulate air filters for general ventilation. These filters are classified according to their performance as measured in this test procedure.
This European Standard contains requirements to be met by particulate air filters. It describes testing methods and the test rig for measuring filter performance.
In order to obtain results for comparison and classification purposes, particulate air filters shall be tested against two synthetic aerosols, a fine aerosol for measurement of filtration efficiency as a function of particle size within a particle size range 0,2 μm to 3,0 μm, and a coarse one for obtaining information about test dust capacity and, in the case of coarse filters, filtration efficiency with respect to coarse loading dust (arrestance).
This European Standard applies to air filters having an initial efficiency of less than 98 % with respect to 0,4 μm particles. Filters shall be tested at an air flow rate between 0,24 m3/s (850 m3/h) and 1,5 m3/s (5400 m3/h).
The performance results obtained in accordance with this standard cannot by themselves be quantitatively applied to predict performance in service with regard to efficiency and lifetime. Other factors influencing performance to be taken into account are described in Annex A (informative).
Standards | Relationship |
I.S. EN 779:2012 | Identical |
SN EN 779 : 2012 | Identical |
UNI EN 779 : 2012 | Identical |
NS EN 779 : 2012 | Identical |
EN 779:2012 | Identical |
NF EN 779 : 2012 | Identical |
UNE-EN 779:2013 | Identical |
NEN EN 779 : 2012 | Identical |
NBN EN 779 : 2012 | Identical |
DIN EN 779:2012-10 | Identical |
DEFSTAN 02-102(PT1)/2(2000) : 2000 | REQUIREMENTS FOR AIR CONDITIONING & VENTILATION - PART 1: HM SURFACE SHIPS AND ROYAL FLEET AUXILIARIES |
DEFSTAN 02-102(PT1)/3(2005) : 2005 | REQUIREMENTS FOR AIR-CONDITIONING AND VENTILATION - PART 1: HM SURFACE SHIPS AND ROYAL FLEET AUXILIARIES |
12/30240811 DC : 0 | BS 8568 - CLEANROOM ENERGY - CODE OF PRACTICE FOR IMPROVING ENERGY EFFICIENCY IN CLEANROOMS AND CLEAN AIR DEVICES |
BS 5454:2000 | Recommendations for the storage and exhibition of archival documents |
PD 5454:2012 | Guide for the storage and exhibition of archival materials |
BS 8568:2013 | Cleanroom energy. Code of practice for improving energy efficiency in cleanrooms and clean air devices |
BS 7083:1996 | Guide to the accommodation and operating environment for information technology (IT) equipment |
11/30232592 DC : 0 | PD 5454 - GUIDE FOR THE STORAGE AND EXHIBITION OF ARCHIVAL MATERIALS |
ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
ISO 2854:1976 | Statistical interpretation of data — Techniques of estimation and tests relating to means and variances |
EN 779:2012 | Particulate air filters for general ventilation - Determination of the filtration performance |
IEST RP CC014.2 : 2010 | CALIBRATION AND CHARACTERIZATION OF OPTICAL AIRBORNE PARTICLE COUNTERS |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ASME MFC 3M : 2004 | MEASUREMENT OF FLUID FLOW IN PIPES USING ORIFICE, NOZZLE, AND VENTURI |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
EN 1822-1:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking |
ISO 21501-4:2007 | Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne particle counter for clean spaces |
ISO 12103-1:2016 | Road vehicles — Test contaminants for filter evaluation — Part 1: Arizona test dust |
ISO 21501-1:2009 | Determination of particle size distribution — Single particle light interaction methods — Part 1: Light scattering aerosol spectrometer |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.