• BS EN IEC 61340-4-4:2018

    Current The latest, up-to-date edition.

    Electrostatics Standard test methods for specific applications. Electrostatic classification of flexible intermediate bulk containers (FIBC)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  13-04-2018

    Publisher:  British Standards Institution

    Add To Cart

    Scope - (Show below) - (Hide below)

    This part of IEC61340 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25m 3 and 3m 3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere can be created by the contents in the FIBC or can exist outside the FIBC. The requirements include: classification and labelling of FIBC; classification of inner liners; specification of test methods for each type of FIBC, inner liner, labels and document pockets; design and performance requirements for FIBC, inner liners, labels and document pockets; safe use of FIBC (including those with inner liners) within different zones defined for explosion endangered environments, described for areas where combustible dusts are, or can be, present ( IEC60079‑10‑2 ), and for explosive gas atmospheres ( IEC60079‑10‑1 ); procedures for type qualification and certification of FIBC, including the safe use of inner liners. NOTE1 Guidance on test methods that can be used for manufacturing quality control is given in AnnexC. The requirements of this document are applicable to all types of FIBC and inner liners, tested as manufactured, prior to use and intended for use in hazardous explosive atmospheres: Zones 1 and 2 (Groups IIA and IIB only) and Zones 21 and 22 (see AnnexD for classification of hazardous areas and explosion groups). For some types of FIBC, the requirements of this document apply only to use in hazardous explosive atmospheres with minimum ignition energy of 0,14mJ or greater and where charging currents do not exceed 3,0µA. NOTE2 0,14mJ represents a realistic minimum ignition energy for a Group IIB gas or vapour atmosphere. Although more sensitive materials exist, 0,14mJ is the lowest minimum ignition energy of any material that is likely to be present when FIBC are emptied. 3,0µA is the highest charging current likely to be found in common industrial processes. This combination of minimum ignition energy and charging current represents the most severe conditions that might be expected in practice. FIBC are not normally used in Zone 0 or Zone 20. If FIBC are used in Zone 0 or Zone 20, the requirements of this document are applicable, together with additional requirements that are beyond the scope of this document to define. The volume contained within FIBC can be designated as Zone 20, in which case the requirements of this document are applicable. Solids containing residual solvent can result in a hazardous explosive atmosphere within FIBC, possibly resulting in the volume being designated as Zone 1 or Zone 2; in which case the requirements of this document are applicable. Compliance with the requirements specified in this document does not necessarily ensure that hazardous electrostatic discharges, for example cone discharges, will not be generated by the contents in FIBC. Information on the risks associated with cone discharges is given in AnnexE. Compliance with the requirements of this document does not mitigate the need for full risk assessment. For example, metal and other conductive powders and toner powders can require additional precautions to prevent hazardous discharges from the powders. NOTE3 In the examples mentioned in the paragraph above, additional precautions can be necessary in the case of metal or other conductive powder because if the powder is isolated and becomes charged, incendiary sparks can occur, and in the case of toner powders, incendiary discharges can occur during rapid filling and emptying operations. IECTS60079‑32‑1 [1] 1 gives guidance on additional precautions that can be necessary. Test methods included in this document can be used in association with other performance requirements, for example when a risk assessment has shown the minimum ignition energy of concern is less than 0,14mJ, charging currents are greater than 3,0µA, or the ambient conditions are outside of the range specified in this document. Compliance with the requirements specified in this document does not necessarily ensure that electric shocks to personnel will not occur from FIBC during normal use.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/101
    Development Note Supersedes BS EN 61340-4-4. (04/2018)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective