• Shopping Cart
    There are no items in your cart

BS EN ISO 10304-3:1997

Current

Current

The latest, up-to-date edition.

Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-10-1997

€231.38
Excluding VAT

1 Scope
2 Normative references
3 Principle
4 Determination of iodide, thiocyanate and thiosulfate
    4.1 Reagents
    4.2 Apparatus
    4.3 Interferences
    4.4 Sampling and sample pretreatment
    4.5 Procedure
    4.6 Calculation
    4.7 Expression of results
    4.8 Test report
5 Determination of sulfite
    5.1 Reagents
    5.2 Apparatus
    5.3 Interferences
    5.4 Sampling and sample pretreatment
    5.5 Procedure
    5.6 Calculation
    5.7 Expression of results
    5.8 Test report
6 Determination of chromate
    6.1 Reagents
    6.2 Apparatus
    6.3 Interferences
    6.4 Sampling and sample pretreatment
    6.5 Procedure
    6.6 Calculation
    6.7 Expression of results
    6.8 Test report
7 Precision
Annex A (informative) Interlaboratory trials
Annex B (informative) Bibliography

Defines procedures for determining in aqueous solution the dissolved anions iodide, thiocyanate and thiosulfate, sulfite and chromate. ALSO NUMBERED AS BS 6068-2.59: 1997

Committee
EH/3/2
DevelopmentNote
Also numbered as BS 6068-2.59(1997) Supersedes 95/520582 DC (09/2005) Reviewed and confirmed by BSI, July 2008. (06/2008)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of ISO 10304 specifies methods for the determination in aqueous solution of the dissolved anions iodide, thiocyanate and thiosulfate (clause 4); sulfite (clause 5); chromate (clause 6). An appropriate pretreatment of the sample (e.g. dilution) and the application of a conductivity detector (CD), UV detector (UV) or amperometric detector (AD) make the working ranges given in table 1 feasible. Table 1 Applicable working ranges Anion Working range1) Detector Chromate (CrO4), clause 6 0,05 mg/l to 50 mg/l UV (λ = 365 nm) Iodide (I), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 236 nm)
AD (approximately 0,7 V to 1,1 V) Sulfite (SO3), clause 5 0,1 mg/l to 50 mg/l
0,5 mg/l to 50 mg/l CD
UV (λ = 205 nm to 220 nm) Thiocyanate (SCN), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V) Thiosuifate (S2O3), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V) 1) The working range is restricted by the exchange capacity of the columns. Dilute the sample into the working range if necessary.

BS PAS 61(2006) : 2006 DETERMINATION OF PRIORITY POLLUTANTS IN SURFACE WATER USING PASSIVE SAMPLING

ISO 5667-2:1991 Water quality Sampling Part 2: Guidance on sampling techniques
ISO 10304-1:2007 Water quality Determination of dissolved anions by liquid chromatography of ions Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 5667-3:2012 Water quality Sampling Part 3: Preservation and handling of water samples
ISO 10304-2:1995 Water quality Determination of dissolved anions by liquid chromatography of ions Part 2: Determination of bromide, chloride, nitrate, nitrite, orthophosphate and sulfate in waste water
ISO 5667-1:2006 Water quality Sampling Part 1: Guidance on the design of sampling programmes and sampling techniques
ISO 8466-1:1990 Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.