BS EN ISO 10304-3:1997
Current
The latest, up-to-date edition.
Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate
Hardcopy , PDF
English
15-10-1997
1 Scope
2 Normative references
3 Principle
4 Determination of iodide, thiocyanate and thiosulfate
4.1 Reagents
4.2 Apparatus
4.3 Interferences
4.4 Sampling and sample pretreatment
4.5 Procedure
4.6 Calculation
4.7 Expression of results
4.8 Test report
5 Determination of sulfite
5.1 Reagents
5.2 Apparatus
5.3 Interferences
5.4 Sampling and sample pretreatment
5.5 Procedure
5.6 Calculation
5.7 Expression of results
5.8 Test report
6 Determination of chromate
6.1 Reagents
6.2 Apparatus
6.3 Interferences
6.4 Sampling and sample pretreatment
6.5 Procedure
6.6 Calculation
6.7 Expression of results
6.8 Test report
7 Precision
Annex A (informative) Interlaboratory trials
Annex B (informative) Bibliography
Defines procedures for determining in aqueous solution the dissolved anions iodide, thiocyanate and thiosulfate, sulfite and chromate. ALSO NUMBERED AS BS 6068-2.59: 1997
Committee |
EH/3/2
|
DevelopmentNote |
Also numbered as BS 6068-2.59(1997) Supersedes 95/520582 DC (09/2005) Reviewed and confirmed by BSI, July 2008. (06/2008)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO 10304 specifies methods for the determination in aqueous solution of the dissolved anions iodide, thiocyanate and thiosulfate (clause 4); sulfite (clause 5); chromate (clause 6). An appropriate pretreatment of the sample (e.g. dilution) and the application of a conductivity detector (CD), UV detector (UV) or amperometric detector (AD) make the working ranges given in table 1 feasible. Table 1 Applicable working ranges Anion Working range1) Detector Chromate (CrO4), clause 6 0,05 mg/l to 50 mg/l UV (λ = 365 nm) Iodide (I), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 236 nm)
AD (approximately 0,7 V to 1,1 V) Sulfite (SO3), clause 5 0,1 mg/l to 50 mg/l
0,5 mg/l to 50 mg/l CD
UV (λ = 205 nm to 220 nm) Thiocyanate (SCN), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V) Thiosuifate (S2O3), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V) 1) The working range is restricted by the exchange capacity of the columns. Dilute the sample into the working range if necessary.
Standards | Relationship |
NS EN ISO 10304-3 : 1ED 1997 | Identical |
I.S. EN ISO 10304-3:1998 | Identical |
NF EN ISO 10304-3 : 1997 | Identical |
ISO 10304-3:1997 | Identical |
SN EN ISO 10304-3 : 1998 | Identical |
NEN EN ISO 10304-3 : 1997 | Identical |
EN ISO 10304-3:1997 | Identical |
NBN EN ISO 10304-3 : 1997 | Identical |
UNI EN ISO 10304-3 : 2000 | Identical |
UNE-EN ISO 10304-3:1997 | Identical |
DIN EN ISO 10304-3:1997-11 | Identical |
BS PAS 61(2006) : 2006 | DETERMINATION OF PRIORITY POLLUTANTS IN SURFACE WATER USING PASSIVE SAMPLING |
ISO 5667-2:1991 | Water quality Sampling Part 2: Guidance on sampling techniques |
ISO 10304-1:2007 | Water quality Determination of dissolved anions by liquid chromatography of ions Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate |
ISO 5667-3:2012 | Water quality Sampling Part 3: Preservation and handling of water samples |
ISO 10304-2:1995 | Water quality Determination of dissolved anions by liquid chromatography of ions Part 2: Determination of bromide, chloride, nitrate, nitrite, orthophosphate and sulfate in waste water |
ISO 5667-1:2006 | Water quality Sampling Part 1: Guidance on the design of sampling programmes and sampling techniques |
ISO 8466-1:1990 | Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.