BS EN ISO 10993-18:2020

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Biological evaluation of medical devices Chemical characterization of medical device materials within a risk management process

Available format(s)

Hardcopy , PDF

Withdrawn date

27-07-2023

Language(s)

English

Published date

14-12-2020

€366.94
Excluding VAT

Committee
CH/194
DocumentType
Standard
Pages
84
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following: the identification of its materials of construction (medical device configuration); the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition); the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues); the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables); the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables). This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO10993-9, ISO10993-13, ISO10993-14 and ISO10993-15.The ISO10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO10993-1 for categorization by nature of body contact).This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

Standards Relationship
EN ISO 10993-18:2020 Identical
ISO 10993-18:2020 Identical