BS EN ISO 1179-1:2013
Current
The latest, up-to-date edition.
Connections for general use and fluid power. Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Threaded ports
Hardcopy , PDF
English
30-11-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Dimensions
5 Test methods
6 Designation of ports
7 Identification statement (reference to this
part of ISO 1179)
Annex A (informative) - Port depths from ISO 1179:1981 used
in pneumatic applications where stud ends interface
with ISO 7-1 male taper threads
Bibliography
Describes dimensions for ports with ISO 228-1 threads for use with non-adjustable stud ends described in ISO 1179-2, ISO 1179-3 and ISO 1179-4 and with adjustable stud ends described in ISO 1179-3.
| Committee |
MCE/18/-/4
|
| DevelopmentNote |
Supersedes 01/714272 DC & 05/30135256 DC. (02/2009) Supersedes 12/30260519 DC. (11/2013)
|
| DocumentType |
Standard
|
| Pages |
18
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of ISO1179 specifies dimensions for ports with ISO228-1 threads for use with non-adjustable stud ends described in ISO1179-2, ISO1179-3 and ISO1179-4 and with adjustable stud ends described in ISO1179-3.
Ports in accordance with this part of ISO1179 are applicable for use with
ISO1179-2 heavy-duty (S series) stud ends with type E sealing at working pressures up to 63MPa (630bar) and light-duty (L series) stud ends at working pressures up to 25MPa (250bar),
ISO1179-3 light-duty (L series) stud ends with type G sealing at working pressures up to 31,5MPa (315bar) and ISO1179-3 light-duty (L series) adjustable stud ends with type H sealing at working pressures up to 20MPa (200bar), and
ISO1179-4 stud ends with type B sealing at working pressures up to 40MPa (400bar) for the S series, up to 25MPa (250bar) for the L series, and up to 10MPa (100bar) for the LL series,
except for the G2 size port, which in hydraulic fluid power systems is used mainly with accumulators and for which ISO1179-3 and ISO1179-4 do not specify stud ends. The permissible working pressure depends upon size, materials, design, working conditions, application, etc.
Users of this part of ISO1179 should ensure that there is sufficient material around the port to maintain the pressure.
NOTE The introduction of this part of ISO1179 gives recommendations for ports and stud ends to be used for new designs in hydraulic and pneumatic fluid power applications.
| Standards | Relationship |
| ISO 1179-1:2013 | Identical |
| EN ISO 1179-1:2013 | Identical |
| I.S. EN ISO 1179-1:2013 | Equivalent |