BS EN ISO 14146:2021

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Radiological protection. Criteria and performance limits for the periodic evaluation of dosimetry services

Amendment of

BS ISO 14146:2018

Available format(s)

Hardcopy , PDF

Superseded date

19-07-2024

Superseded by

BS EN ISO 14146:2024

Language(s)

English

Published date

19-02-2021

€175.29
Excluding VAT

Committee
NCE/2
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

The quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type‑tested) dosimetry system1 and the training and experience of the staff, together with the calibration procedures and quality assurance programmes.

This document specifies the criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area dosemeters.

An area dosemeter can be a workplace dosemeter or an environmental dosemeter.

The performance evaluation can be carried out as a part of the approval procedure for a dosimetry system or as an independent check to verify that a dosimetry service fulfils specified national or international type test performance requirements under representative exposure conditions that are expected or mimic workplace fields from the radiological activities being monitored.

This document applies to personal and area dosemeters for the assessment of external photon radiation with a (fluence weighted) mean energy between8keV and10MeV, beta radiation with a (fluence weighted) mean energy between60keV and1,2MeV, and neutron radiation with a (fluence weighted) mean energy between25,3meV (i.e. thermal neutrons with a Maxwellian energy distribution withkT=25,3meV) and200MeV.

It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month).

Active dosemeters (for dose measurement) may also be treated according to this document. Then, they should be treated as if they were passive (i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization).

1 If this document is applied to a dosimetry system for which no approval (pattern or type test) has been provided, then in the following text approval or type test should be read as the technical data sheet provided by the manufacturer or as the data sheet required by the regulatory authority.

Standards Relationship
ISO 14146:2018 Identical
EN ISO 14146:2021 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.