BS EN ISO 15681-1:2004
Current
The latest, up-to-date edition.
Water quality. Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) Method by flow injection analysis (FIA)
Hardcopy , PDF
English
11-02-2005
Foreword
Introduction
1 Scope
2 Normative references
3 Interferences
3.1 General interferences
3.2 Interferences in the determination of total-P
4 Principle
4.1 Determination of orthophosphate
4.2 Total phosphorus with manual digestion
5 Reagents
6 Apparatus
6.1 Flow injection analysis (FIA)
6.2 Additional apparatus
6.3 Additional apparatus for the determination of total
phosphorus
7 Sampling and sample preparation
8 Procedure
8.1 Analysis preparation
8.2 Instrument performance check
8.3 Reagent blank check
8.4 Calibration
8.5 Check of digestion efficiency for determination of
total-P
8.6 Measurement
8.7 Closing down the system
9 Calculation of results
10 Expression of results
11 Test report
Annex A (informative) Example of an FIA system
Annex B (informative) Precision and accuracy
Annex C (informative) Determination of orthophosphate-P and
total-P by FIA using ascorbic acid
reduction
Annex D (informative) Replacement of hydrazine sulfate by DEHA
(N,N-diethylhydroxylamine)
Bibliography
Provides flow injection analysis (FIA) methods for the determination of orthophosphate in the mass concentration range from 0,01 mg/l to 1,0 mg/l (P), and total phosphorus by manual digestion in accordance with ISO 6878 for the mass concentration range from 0,1 mg/l to 10 mg/l (P). Applicable to various types of water (such as ground, drinking, surface, leachate and waste waters).
Committee |
EH/3/2
|
DevelopmentNote |
Renumbers and supersedes BS ISO 15681-1. 2004 version incorporates amendment 15545 to BS ISO 15681-1. Also numbered as BS 6068-2.86(2004). Supersedes BS 6068-2.86(2003) and 01/562317 DC. (02/2005) Reviewed and confirmed by BSI, July 2009. (06/2009)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
ISO 15681-1:2003 | Identical |
SN EN ISO 15681-1 : 2005 | Identical |
UNE-EN ISO 15681-1:2005 | Identical |
DIN EN ISO 15681-1:2005-05 | Identical |
UNI EN ISO 15681-1 : 2005 | Identical |
NBN EN ISO 15681-1 : 2005 | Identical |
NEN EN ISO 15681-1 : 2005 | Identical |
NF EN ISO 15681-1 : 2005 | Identical |
NS EN ISO 15681-1 : 1ED 2005 | Identical |
I.S. EN ISO 15681-1:2005 | Identical |
EN ISO 15681-1:2004 | Identical |
BS PAS 61(2006) : 2006 | DETERMINATION OF PRIORITY POLLUTANTS IN SURFACE WATER USING PASSIVE SAMPLING |
ISO 5667-2:1991 | Water quality Sampling Part 2: Guidance on sampling techniques |
ISO 15681-2:2003 | Water quality Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) Part 2: Method by continuous flow analysis (CFA) |
ISO 5667-3:2012 | Water quality Sampling Part 3: Preservation and handling of water samples |
ISO 5667-1:2006 | Water quality Sampling Part 1: Guidance on the design of sampling programmes and sampling techniques |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 8466-1:1990 | Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function |
ISO 6878:2004 | Water quality — Determination of phosphorus — Ammonium molybdate spectrometric method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.