• BS EN ISO 16000-5:2007

    Current The latest, up-to-date edition.

    Indoor air Sampling strategy for volatile organic compounds (VOCs)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-03-2007

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Definition of volatile organic compounds (VOCs)
    4 Sources and occurrence
    5 Measurement technique
      5.1 General
      5.2 Short-term measurements
      5.3 Long-term measurements
    6 Sampling and measurement planning
      6.1 General
      6.2 Measurement objective and environmental conditions
      6.3 Time of sampling
      6.4 Duration of sampling and frequency of measurement
      6.5 Sampling location
      6.6 Presentation of results and measurement uncertainty
      6.7 Quality assurance
    Annex A (informative) Examples of organic chemicals detected
            in indoor air
    Annex B (informative) Protocol for recording activities
            and boundary conditions during sampling
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides an aid to planning volatile organic compound (VOC) indoor pollution measurements.

    Scope - (Show below) - (Hide below)

    This part of ISO 16000 is intended as an aid to planning volatile organic compound (VOC) indoor pollution measurements. In the case of indoor air measurements, the careful planning of sampling and the entire measurement strategy are of particular significance since the result of the measurement may have far-reaching consequences, for example, with regard to the need for remedial action or the success of such an action.

    An inappropriate measurement strategy may contribute to the complete uncertainty of the measurement result in a larger extent than the measurement procedure itself.

    This part of ISO 16000 uses the definition for indoor environment defined in ISO 16000-1.

    General Product Information - (Show below) - (Hide below)

    Committee EH/2/3
    Development Note Supersedes 05/30108617 DC. (03/2007) Reviewed and confirmed by BSI, July 2010. (06/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 16000-4:2011 Indoor air Part 4: Determination of formaldehyde Diffusive sampling method
    VDI 4300 Blatt 6:2000-12 Measurement of indoor air pollution - Measurement strategy for volatile organic compounds (VOCs)
    ISO 7243:2017 Ergonomics of the thermal environment — Assessment of heat stress using the WBGT (wet bulb globe temperature) index
    ISO 16017-1:2000 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling
    ISO 16017-2:2003 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling
    ISO/TR 11079:1993 Evaluation of cold environments — Determination of required clothing insulation (IREQ)
    ISO 7933:2004 Ergonomics of the thermal environment — Analytical determination and interpretation of heat stress using calculation of the predicted heat strain
    ISO 7730:2005 Ergonomics of the thermal environment — Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
    ISO 16000-3:2011 Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method
    ISO 16000-2:2004 Indoor air — Part 2: Sampling strategy for formaldehyde
    ISO 16000-1:2004 Indoor air — Part 1: General aspects of sampling strategy
    ISO 16000-8:2007 Indoor air Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions
    ISO 16000-10:2006 Indoor air Part 10: Determination of the emission of volatile organic compounds from building products and furnishing Emission test cell method
    ISO 16000-6:2011 Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective