BS EN ISO 19581:2020

Current

Current

The latest, up-to-date edition.

Measurement of radioactivity. Gamma emitting radionuclides. Rapid screening method using scintillation detector gamma-ray spectrometry

Amendment of

BS ISO 19581:2017

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

26-03-2020

€217.36
Excluding VAT

This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563).

Committee
NCE/2
DocumentType
Standard
ISBN
9780539133899
Pages
30
ProductNote
This corrigendum renumbers BS ISO 19581:2017 as BS EN ISO 19581:2020
PublisherName
British Standards Institution
Status
Current

This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as131I,132Te,134Cs and137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC61563).

This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other international standards for sampling procedures that can be used in combination with this document are available (see References [1],[2],[3],[4],[5],[6]).

The test method applies to the measurement of gamma-emitting radionuclides such as131I,134Cs and137Cs. Using sample sizes of 0,5l to 1,0l in a Marinelli beaker and a counting time of 5 min to 20 min, decision threshold of 10Bq·kg−1 can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodine (NaI(Tl)) spectrometer 2”ϕ×2” detector size, 7% resolution (FWHM) at 662 keV, 30mm lead shield thickness].

This test method also can be performed in a “makeshift” laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected.

During a nuclear or radiological emergency, this test method enables a rapid measurement of the sample activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predetermined emergency response to reduce existing radiation risks[12].

Due to the uncertainty associated with the results obtained with this test method, test samples requiring more accurate test results can be measured using high-purity germanium (HPGe) detectors gamma-ray spectrometry in a testing laboratory, following appropriate preparation of the test samples[7][8].

This document does not contain criteria to establish the activity concentration of OILs.

Standards Relationship
ISO 19581:2017 Identical
EN ISO 19581:2020 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.