• Shopping Cart
    There are no items in your cart

BS EN ISO 3651-1:1998

Current

Current

The latest, up-to-date edition.

Determination of resistance to intergranular corrosion of stainless steels Austenitic and ferritic-austenitic (duplex) stainless steels. Corrosion test in nitric acid medium by measurement of loss in mass (Huey test)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-07-1998

€165.94
Excluding VAT

National foreword
Foreword
Introduction
1 Scope
2 Purpose of the test
3 Heat treatment of sensitization
4 Corrosion test
5 Apparatus
6 Corrosive solution
7 Procedure
8 Calculation
9 Test report

Defines a method for the determination of the resistance to intergranular corrosion of austenitic and ferritic-austenitic (duplex) stainless steels in a nitric acid medium by measurement of the loss in mass (Huey test).

Committee
ISE/1
DevelopmentNote
Supersedes 96/710733 DC. (10/2005)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of ISO 3651 specifies a method for the determination of the resistance to intergranular corrosion of austenitic and ferritic-austenitic (duplex) stainless steels in a nitric acid medium by measurement of the loss in mass (Huey test). It also specifies the purpose which may be assigned to the test.

The method is applicable only to austenitic and ferritic-austenitic (duplex) stainless steels supplied in the form of rolled or forged products, tubes and cast products and intended for use in a strongly oxidizing medium (for example, relatively concentrated nitric acid). In general the Huey test should not be used for grades containing molybdenum unless the material tested is to be used in nitric acid service.

NOTE - It is important to note that the result of the corrosion test is only strictly valid for the corrosive medium used in the test. It constitutes a basis for estimating the resistance to intergranular corrosion but may not be used to check resistance to other forms of corrosion (general corrosion, pitting, stress corrosion, etc.). It is necessary for the user to adapt the specified corrosion test to the use which will be made of the alloy. This test should, in no case, be considered as an absolute criterion of the quality of the alloy.

12/30270377 DC : 0 BS S 537+A2 - SPECIFICATION FOR LOW CARBON 17/12 CHROMIUM-NICKEL-MOLYBDENUM CORROSION-RESISTING STEEL SHEET AND STRIP (500 MPA)
12/30270375 DC : 0 BS S 536+A2 - SPECIFICATION FOR LOW CARBON 18/10 CHROMIUM-NICKEL CORROSION-RESISTING STEEL SHEET AND STRIP (500 MPA)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.