• There are no items in your cart

BS EN ISO 3744:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Acoustics. Determination of sound power levels of noise sources using sound pressure. Engineering method in an essentially free field over a reflecting plane

Available format(s)

Hardcopy , PDF

Superseded date

31-01-2011

Language(s)

English

Published date

30-04-2010

1.1 General This International Standard specifies a method for measuring the sound pressure levels on a measurement surface enveloping a noise source, under essentially free-field conditions near one or more reflecting planes, in order to calculate the sound power level produced by the noise source. It gives requirements for the test environment and instrumentation, as well as techniques for obtaining the surface sound pressure level from which the sound power level of the source is calculated, leading to results which have a grade 2 accuracy. It is important that specific noise test codes for various types of equipment be established and used in accordance with this International Standard. For each type of equipment, such noise test codes will give detailed requirements on mounting, loading and operating conditions for the equipment under test as well as a selection of the measurement surface and the microphone array as specified in this International Standard. NOTE 1 The noise test code for a particular type of equipment should give detailed information on the particular surface that is selected, as the use of differently shaped measurement surfaces may yield differing estimates of the sound power level of a source. 1.2 Types of noise and noise sources The method specified in this International Standard is suitable for measurements of all types of noise. NOTE 2 A classification of different types of noise (steady, non-steady, quasi-steady, impulsive, etc.) is given in ISO 2204. This International Standard is applicable to noise sources of any type and size (e.g. device, machine, component, sub-assembly). NOTE 3 Measurements according to this International Standard may be impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi­source industrial plants. 1.3 Test environment The test environment that is applicable for measurements made in accordance with this International Standard is an essentially free field near one or more reflecting planes (indoors or outdoors). 1.4 Measurement uncertainty Determinations made in accordance with this International Standard result, with few exceptions, in standard deviations of reproducibility of the A­weighted sound power level equal to or less than 1,5 dB (see table 1). A single value of the sound power level of a noise source determined according to the procedures given in this International Standard is likely to differ from the true value by an amount within the range of the measurement uncertainty. The uncertainty in determinations of the sound power level arises from several factors which affect the results, some associated with environmental conditions in the measurement laboratory and others with experimental techniques. If a particular noise source were to be transported to each of a number of different laboratories, and if, at each laboratory, the sound power level of that source were to be determined in accordance with this International Standard, the results would show a scatter. The standard deviation of the measured levels could be calculated (see examples in ISO 7574-4:1985, annex B) and would vary with frequency. With few exceptions, these standard deviations would not exceed those listed in table 1. The values given in table 1 are standard deviations of reproducibility, σR, as defined in ISO 7574-1. The values of table 1 take into account the cumulative effects of measurement uncertainty in applying the procedures of this International Standard, but exclude variations in the sound power output caused by changes in operating conditions (e.g. rotational speed, line voltage) or mounting conditions. The measurement uncertainty depends on the standard deviation of reproducibility tabulated in table 1 and on the degree of confidence that is desired. As examples, for a normal distribution of sound power levels, there is 90 % confidence that the true value of the sound power level of a source lies within the range ± 1,645 σR of the measured value and a 95 % confidence that it lies within the range ± 1,96 σR of the measured value. For further examples, reference should be made to the ISO 7574 series and ISO 9296. Table 1 - Estimated values of the standard deviations of reproducibility of sound power levels determined in accordance with this International Standard Octave-band centre frequencies One-third-octave band centre frequencies Standard deviation of reproducibility σR Hz Hz dB 63 125 250 500 to 4 000 8 000 50 to 80 100 to 160 200 to 315 400 to 5 000 6 300 to 10 000 5 1) 3 2 1,5 2,5 A-weighted 1,5 2) 1) Normally for outdoor measurements; many rooms are not qualified for this frequency band. 2) Applicable to a source which emits noise with a relatively \'flat\' spectrum in the frequency range 1 00 Hz to 10 000 Hz. NOTES 4 The standard deviations listed in table 1 are associated with the test conditions and procedures defined in this International Standard and not with the noise source itself. They arise in part from variations between measurement laboratories, changes in atmospheric conditions if outdoors, the geometry of the test room or outdoor environment, the acoustical properties of the reflecting plane, absorption at the test room boundaries if indoors, background noise, and the type and calibration of instrumentation. They are also due to variations in experimental techniques, including the size and shape of the measurement surface, number and location of microphone positions, sound source location. integration times, and determination of environmental corrections, if any. The standard deviations are also affected by errors associated with measurements taken in the near field of the source; such errors depend upon the nature of the sound source, but generally increase for smaller measurement distances and lower frequencies (below 250 Hz). 5 If several laboratories use similar facilities and instrumentation, the results of sound power determinations on a given source in those laboratories may be in better agreement than would be implied by the standard deviations of table 1. 6 For a particular family of sound sources, of similar size with similar sound power spectra and similar operating conditions, the standard deviations of reproducibility may be smaller than the values given in table 1. Hence, a noise test code for a particular type of machinery or equipment making reference to this International Standard may state standard deviations smaller than those listed in table 1, if substantiation is available from the results of suitable interlaboratory tests. 7 The standard deviations of reproducibility, as tabulated in table 1, include the uncertainty associated with repeated measurements on the same noise source under the same conditions (for standard deviation of repeatability, see ISO 7574-1). This uncertainty is usually much smaller than the uncertainty associated with interlaboratory variability. However, if it is difficult to maintain stable operating or mounting conditions for a particular source, the standard deviation of repeatability may not be small compared with the values given in table 1. In such cases, the fact that it was difficult to obtain repeatable sound power level data on the source should be recorded and stated in the test report. 8 The procedures of this International Standard and the standard deviations given in table 1 are applicable to measurements on an individual machine. Characterization of the sound power levels of batches of machines of the same family or type involves the use of random sampling techniques in which confidence intervals are specified, and the results are expressed in terms of statistical upper limits. In applying these techniques, the total standard deviation must be known or estimated, including the standard deviation of production, as defined in ISO 7574-1, which is a measure of the variation in sound power output between individual machines within the batch. Statistical methods for the characterization of batches of machines are described in ISO 7574-4.

Committee
EH/1/4
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN ISO 3744:2009 Identical
ISO 3744:1994 Identical

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.