BS EN ISO 4037-2:2021
Current
The latest, up-to-date edition.
Radiological protection. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
Hardcopy , PDF
English
22-02-2021
Committee |
NCE/2
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document specifies the procedures for the dosimetry of X and gamma reference radiation for the calibration of radiation protection instruments over the energy range from approximately 8keV to 1,3MeV and from 4MeV to 9MeV and for air kerma rates above 1µGy/h. The considered measuring quantities are the air kerma free-in-air, Ka, and the phantom related operational quantities of the International Commission on Radiation Units and Measurements (ICRU)[2], H*(10), Hp(10), H\'(3), Hp(3), H\'(0,07) and Hp(0,07), together with the respective dose rates. The methods of production are given in ISO4037‑1. This document can also be used for the radiation qualities specified in ISO4037‑1:2019, Annexes A, B and C, but this does not mean that a calibration certificate for radiation qualities described in these annexes is in conformity with the requirements of ISO4037. The requirements and methods given in this document are targeted at an overall uncertainty (k=2) of the dose(rate) of about 6% to 10% for the phantom related operational quantities in the reference fields. To achieve this, two production methods of the reference fields are proposed in ISO4037‑1. The first is to produce “matched reference fields”, which follow the requirements so closely that recommended conversion coefficients can be used. The existence of only a small difference in the spectral distribution of the “matched reference field” compared to the nominal reference field is validated by procedures, which are given and described in detail in this document. For matched reference radiation fields, recommended conversion coefficients are given in ISO4037‑3only for specified distances between source and dosemeter, e.g., 1,0m and 2,5m. For other distances, the user has to decide if these conversion coefficients can be used. The second method is to produce “characterized reference fields”. Either this is done by determining the conversion coefficients using spectrometry, or the required value is measured directly using secondary standard dosimeters. This method applies to any radiation quality, for any measuring quantity and, if applicable, for any phantom and angle of radiation incidence. The conversion coefficients can be determined for any distance, provided the air kerma rate is not below 1µGy/h. Both methods require charged particle equilibrium for the reference field. However this is not always established in the workplace field for which the dosemeter shall be calibrated. This is especially true at photon energies without inherent charged particle equilibrium at the reference depth d, which depends on the actual combination of energy and reference depth d. Electrons of energies above 65keV, 0,75MeV and 2,1MeV can just penetrate 0,07mm, 3mm and 10mm of ICRU tissue, respectively, and the radiation qualities with photon energies above these values are considered as radiation qualities without inherent charged particle equilibrium for the quantities defined at these depths. This document is not applicable for the dosimetry of pulsed reference fields.
Standards | Relationship |
ISO 4037-2:2019 | Identical |
EN ISO 4037-2:2021 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.