BS EN ISO 80601-2-70:2020

Current

Current

The latest, up-to-date edition.

Medical electrical equipment Particular requirements for the basic safety and essential performance of sleep apnoea breathing therapy equipment

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-11-2020

€366.94
Excluding VAT

Committee
CH/121
DocumentType
Standard
Pages
80
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC60601‑1:2005+AMD1:2012+AMD2:2020, Clause1 applies, except as follows:

NOTE The general standard is IEC60601‑1:2005+AMD1:2012+AMD2:2020.

201.1.1 Scope

IEC60601‑1:2005+Amendment1:2012, 1.1 is replaced by:

This document is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the respiratory tract of the patient. Sleep apnoea breathing therapy equipment is intended for use in the home healthcare environment by lay operators as well as in professional healthcare institutions.

*Sleep apnoea breathing therapy equipment is not considered to utilize a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the therapy settings.

This document excludes sleep apnoea breathing therapy equipment intended for use with neonates.

This document is applicable to ME equipment or an ME system intended for those patients who are not dependent on mechanical ventilation.

This document is not applicable to ME equipment or an ME system intended for those patients who are dependent on mechanical ventilation such as patients with central sleep apnoea.

This document is also applicable to those accessories intended by their manufacturer to be connected to sleep apnoea breathing therapy equipment, where the characteristics of those accessories can affect the basic safety or essential performance of the sleep apnoea breathing therapy equipment.

Masks and application accessories intended for use during sleep apnoea breathing therapy are additionally addressed by ISO17510. Refer to FigureAA.1 for items covered further under this document.

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.

NOTE See also 4.2 of the general standard.

This document is not applicable to high‐frequency jet ventilators (HFJVs) or high‐frequency oscillatory ventilators (HFOVs), which are given in ISO80601‑2‑87[13].

This document does not specify the requirements for ventilators or accessories intended for critical care ventilators for ventilator‐dependent patients, which are given in ISO80601‑2‑12.

This document does not specify the requirements for ventilators or accessories intended for anaesthetic applications, which are given in ISO80601‑2‑13[8].

This document does not specify the requirements for ventilators or accessories intended for home care ventilators for ventilator‐dependent patients, which are given in ISO80601‑2‑72[9].

This document does not specify the requirements for ventilators or accessories intended for emergency and transport, which are given in ISO80601‑2‑84[12].

This document does not specify the requirements for ventilators or accessories intended for home‐care ventilatory support, which are given in ISO80601‑2‑79[10] and ISO80601‑2‑80[11].

201.1.2 Object

IEC60601‑1:2005, 1.2 is replaced by:

The object of this document is to establish particular basic safety and essential performance requirements for sleep apnoea breathing therapy equipment (as defined in 201.3.215).

NOTE1 This document has been prepared to address the relevant essential principles[17] and labelling[18] guidances of the International Medical Devices Regulators Forum (IMDRF) as indicated in AnnexCC.

NOTE2 This document has been prepared to address the relevant essential principles of safety and performance of ISO16142‑1:2016 as indicated in AnnexDD.

NOTE3 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745[16] as indicated in AnnexEE.

201.1.3 Collateral standards

IEC60601‑1:2005+AMD1:2012+AMD2:2020, 1.3 applies with the following addition:

IEC60601‑1‑2:2014+AMD1:2020 and IEC60601‑1‑6:2010+AMD1:2013+AMD2:2020 apply as modified in Clauses202 and 206 respectively. IEC60601‑1‑3:2008+AMD1:2013 does not apply. All other published collateral standards in the IEC60601‑1 series apply as published.

201.1.4 Particular standards

Replacement:

In the IEC60601 series, particular standards define basic safety and essential performance requirements, and may modify, replace or delete requirements contained in the general standard and collateral standards as appropriate for the particular ME equipment under consideration.

A requirement of a particular standard takes priority over the general standard.

For brevity, IEC60601‑1+AMD1:2012+AMD2:2020 is referred to in this document as the general standard. Collateral standards are referred to by their document number.

The numbering of clauses and subclauses of this document corresponds to that of the general standard with the prefix “201” (e.g. 201.1 in this document addresses the content of Clause1 of the general standard) or applicable collateral standard with the prefix “20x”, where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this document addresses the content of Clause4 of the IEC60601‑1‑2 collateral standard, 203.4 in this document addresses the content of Clause4 of the IEC60601‑1‑3 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words:

\'Replacement\' means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this document.

\'Addition\' means that the text of this document is additional to the requirements of the general standard or applicable collateral standard.

\'Amendment\' means that the clause or subclause of the general standard or applicable collateral standard is amended as indicated by the text of this document.

Subclauses, figures or tables which are additional to those of the general standard are numbered starting from 201.101. However, due to the fact that definitions in the general standard are numbered 3.1 through 3.139, additional definitions in this document are numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc.

Subclauses, figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where “x” is the number of the collateral standard, e.g. 202 for IEC60601‑1‑2, 211 for IEC60601‑1‑11, etc.

The term \'this document\' is used to make reference to the general standard, any applicable collateral standards and this document taken together.

Where there is no corresponding clause or subclause in this document, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect is given in this document.