BS EN ISO 8253-2:2009
Current
The latest, up-to-date edition.
Acoustics. Audiometric test methods Sound field audiometry with pure-tone and narrow-band test signals
Hardcopy , PDF
English
28-02-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test signal characteristics
5 Sound field characteristics
6 Ambient noise levels in the test room
7 Preparation and instruction of test subject
8 Determination of hearing threshold level
9 Testing with a hearing aid
10 Screening audiometry
11 Reporting of data
12 Maintenance and calibration of equipment
Annex A (informative) - Graphical display of results
Annex B (informative) - Correction values for 45 degree
and 90 degree angles of incidence
Bibliography
Describes relevant test signal characteristics, requirements for free, diffuse, and quasi-free sound fields, and procedures for sound field audiometry using pure-tones, frequency-modulated tones or other narrow-band test signals presented by means of one or more loudspeakers.
Committee |
EH/1
|
DevelopmentNote |
Renumbers and supersedes BS 7636(1993) (07/2004) Supersedes 90/51782 DC 1998 Version incorporates amendment 10028 to BS 7636(1993) (06/2005)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO8253 specifies relevant test signal characteristics, requirements for free, diffuse, and quasi-free sound fields, and procedures for sound field audiometry using pure tones, frequency-modulated tones or other narrow-band test signals presented by means of one or more loudspeakers. The primary purpose is the determination of hearing threshold levels in the frequency range 125Hz to 8000Hz, but this range can be extended to 20Hz to 16000Hz.
This part of ISO8253 does not include specifications for the use of hand-held loudspeakers. Speech as a test signal is not covered.
The purpose of this part of ISO8253 is to ensure that tests of hearing, using sound field audiometry, give as high a degree of accuracy and reproducibility as possible.
Examples of graphical representations of the results are given in AnnexA.
Standards | Relationship |
NS EN ISO 8253-2 : 2009 | Identical |
I.S. EN ISO 8253-2:2009 | Identical |
NEN EN ISO 8253-2 : 2010 | Identical |
NBN EN ISO 8253-2 : 2010 | Identical |
UNE-EN ISO 8253-2:2010 | Identical |
ISO 8253-2:2009 | Identical |
EN ISO 8253-2:2009 | Identical |
UNI EN ISO 8253-2 : 2010 | Identical |
NF EN ISO 8253-2 : 2010 | Identical |
IEC 60581-7:1986 | High fidelity audio equipment and systems: Minimum performancerequirements. Part 7: Loudspeakers |
ISO 389-7:2005 | Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions |
ISO 266:1997 | Acoustics — Preferred frequencies |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
ISO 226:2003 | Acoustics — Normal equal-loudness-level contours |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.