BS EN ISO 8638:2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Cardiovascular implants and extracorporeal systems. Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters

Available format(s)

Hardcopy , PDF

Superseded date

03-10-2018

Superseded by

BS EN ISO 8637-2:2018

Language(s)

English

Published date

31-03-2014

€231.38
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Labelling
Bibliography
Annex ZA (informative) - Relationship
         between this European Standard
         and the Essential Requirements
         of EU Directive 93/42/EEC on
         medical devices

Defines requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators (hereafter referred to as 'the device') and (integral and non-integral) transducer protectors which are intended for use in haemodialysis, haemodiafiltration and haemofiltration.

Committee
CH/150/2
DevelopmentNote
Together with BS EN ISO 8637, It supersedes BS EN 1283. Supersedes 13/30280722 DC. (04/2014)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This International Standard specifies requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators (hereafter referred to as “the device”) and (integral and non-integral) transducer protectors which are intended for use in haemodialysis, haemodiafiltration and haemofiltration. This International Standard does not apply to:

  • haemodialysers, haemodiafilters or haemofilters;

  • plasmafilters;

  • vascular access devices;

  • blood pumps;

  • pressure monitors for the extracorporeal blood circuit;

  • air detection devices;

  • systems or equipment intended to perform haemodialysis, haemodiafiltration, haemofiltration or haemoconcentration.

NOTE Requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators are specified in ISO 8637.

Standards Relationship
EN ISO 8638:2014 Identical
ISO 8638:2010 Identical

ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
ISO 8637:2010 Cardiovascular implants and extracorporeal systems Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
ISO/TS 17665-2:2009 Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
ISO 11137-2:2013 Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO/TS 11135-2:2008 Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.